Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector.

Fujio Araki1, Tohru Ikegami, Tatsuyo Ishidoya, Hideo D Kubo.   

Abstract

A radiophotoluminescent (RPL) glass rod dosimeter (GRD) and a small active volume p-type silicon diode detector are used for the measurement of the output factors from Gamma-Knife fields. The GRD system consists of small rod-shaped glass chip detectors and an automatic readout device. The output factors measured with the GRD from the 14, 8 and 4 mm helmets relative to the 18 mm helmet are 0.981, 0.942 and 0.877, respectively. Similarly, the corresponding output factors measured with the p-type silicon diode detector are 0.980, 0.949 and 0.867, respectively. The output factors are corrected for the end effect for each helmet. The output factors obtained from both detectors are in good agreement with the values in a recent publication and the values recommended by Elekta, the manufacturer. The directional dependence of these detectors is also measured. For the Gamma-Knife angle ranging from 6 to 36 degrees in the y-z plane of the stereotactic space, the measured angular dependence of the GRD is approximately 1.0% at a 4 MV x-ray beam. The response of the silicon diode detector indicates approximately 3-4% directional dependence for the same angular range for a 6 MV x-ray beam. The Gamma-Knife helmet output factors measured with the silicon diode detector are corrected for angular dependence.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12945963     DOI: 10.1118/1.1587451

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Development of a stereotactic device for gamma knife irradiation of small animals.

Authors:  Hyun-Tai Chung; Young Seob Chung; Dong Gyu Kim; Sun Ha Paek; Keun-Tae Cho
Journal:  J Korean Neurosurg Soc       Date:  2008-01-20

2.  Small-field dosimetry with detector-specific output correction factor for single-isocenter stereotactic radiotherapy of single and multiple brain metastases.

Authors:  Tomohiro Ono; Kohei Kawata; Mitsuhiro Nakamura; Megumi Uto; Takashi Mizowaki
Journal:  Radiol Phys Technol       Date:  2022-10-22

3.  On the quantification of the dosimetric accuracy of collapsed cone convolution superposition (CCCS) algorithm for small lung volumes using IMRT.

Authors:  Oscar I Calvo; Alonso N Gutiérrez; Sotirios Stathakis; Carlos Esquivel; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

4.  Radiosurgery for cerebral arteriovenous malformation during pregnancy: A case report focusing on fetal exposure to radiation.

Authors:  Kazuki Nagayama; Hiroki Kurita; Ayako Tonari; Makoto Takayama; Yoshiaki Shiokawa
Journal:  Asian J Neurosurg       Date:  2010-07

5.  Multicentre dose audit for clinical trials of radiation therapy in Asia.

Authors:  Hideyuki Mizuno; Shigekazu Fukuda; Akifumi Fukumura; Yuzuru-Kutsutani Nakamura; Cao Jianping; Chul-Koo Cho; Nana Supriana; To Anh Dung; Miriam Joy Calaguas; C R Beena Devi; Yaowalak Chansilpa; Parvin Akhter Banu; Masooma Riaz; Surya Esentayeva; Shingo Kato; Kumiko Karasawa; Hirohiko Tsujii
Journal:  J Radiat Res       Date:  2017-05-01       Impact factor: 2.724

6.  Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification.

Authors:  Shih-Ming Hsu; Chao-Hsiung Hung; Yi-Jen Liao; Hsiao-Mei Fu; Jo-Ting Tsai; Yung-Hui Huang; David Y C Huang
Journal:  PLoS One       Date:  2017-01-03       Impact factor: 3.240

7.  A study on the dose distributions in various materials from an Ir-192 HDR brachytherapy source.

Authors:  Shih-Ming Hsu; Chin-Hui Wu; Jeng-Hung Lee; Ya-Ju Hsieh; Chun-Yen Yu; Yi-Jen Liao; Li-Cheng Kuo; Ji-An Liang; David Y C Huang
Journal:  PLoS One       Date:  2012-09-05       Impact factor: 3.240

8.  Thermoluminescence Response of Ge-Doped Cylindrical-, Flat- and Photonic Crystal Silica-Fibres to Electron and Photon Radiation.

Authors:  A Entezam; M U Khandaker; Y M Amin; N M Ung; D A Bradley; J Maah; M J Safari; F Moradi
Journal:  PLoS One       Date:  2016-05-05       Impact factor: 3.240

9.  A novel and effective method for validation and measurement of output factors for Leksell Gamma Knife® Icon™ using TRS 483 protocol.

Authors:  Swapna Lilly Cyriac; Jian Liu; Emel Calugaru; Jenghwa Chang
Journal:  J Appl Clin Med Phys       Date:  2020-09-06       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.