Literature DB >> 12944606

CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy--comparison of image-guidance techniques.

Christoph A Binkert1, Francis R Verdun, Marco Zanetti, Christian W Pfirrmann, Juerg Hodler.   

Abstract

PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography.
MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software.
RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv.
CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose. Copyright RSNA, 2003

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12944606     DOI: 10.1148/radiol.2291020314

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

Authors:  Carmelo Messina; Giuseppe Banfi; Alberto Aliprandi; Giovanni Mauri; Francesco Secchi; Francesco Sardanelli; Luca Maria Sconfienza
Journal:  Eur Radiol       Date:  2015-08-08       Impact factor: 5.315

2.  Newly developed application system for CT-guided puncture based on multidetector row CT without CT fluoroscopy.

Authors:  Toshiyuki Irie; Masashi Kuramochi
Journal:  Radiat Med       Date:  2007-10-26

3.  Freehand direct arthrography of the shoulder using near real-time guidance in an open 1.0-T MRI scanner.

Authors:  Christian Wybranski; Ilya Adamchic; Friedrich-Wilhelm Röhl; Jens Ricke; Frank Fischbach; Katharina Fischbach
Journal:  Skeletal Radiol       Date:  2016-10-22       Impact factor: 2.199

4.  CT-guided percutaneous biopsy of spinal lesions.

Authors:  Wcg Peh
Journal:  Biomed Imaging Interv J       Date:  2006-07-01

5.  Comparison of image quality of shoulder CT arthrography conducted using 120 kVp and 140 kVp protocols.

Authors:  Se Jin Ahn; Sung Hwan Hong; Jee Won Chai; Ja-Young Choi; Hye Jin Yoo; Sae Hoon Kim; Heung Sik Kang
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

6.  Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

Authors:  Matthieu J C M Rutten; James M P Collins; Bas J Maresch; Jacques H J M Smeets; Caroline M M Janssen; Lambertus A L M Kiemeney; Gerrit J Jager
Journal:  Eur Radiol       Date:  2008-10-29       Impact factor: 5.315

7.  Body-Mounted Robotic System for MRI-Guided Shoulder Arthrography: Cadaver and Clinical Workflow Studies.

Authors:  Niravkumar Patel; Jiawen Yan; Gang Li; Reza Monfaredi; Lukasz Priba; Helen Donald-Simpson; Joyce Joy; Andrew Dennison; Andreas Melzer; Karun Sharma; Iulian Iordachita; Kevin Cleary
Journal:  Front Robot AI       Date:  2021-05-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.