Literature DB >> 12942975

Input-output functions for stimulus-frequency otoacoustic emissions in normal-hearing adult ears.

Kim S Schairer1, Denis Fitzpatrick, Douglas H Keefe.   

Abstract

Input-output (I/O) functions for stimulus-frequency (SFOAE) and distortion-product (DPOAE) otoacoustic emissions were recorded in 30 normal-hearing adult ears using a nonlinear residual method. SFOAEs were recorded at half octaves from 500-8000 Hz in an L1=L2 paradigm with L2=0 to 85 dB SPL, and in a paradigm with L1 fixed and L2 varied. DPOAEs were elicited with primary levels of Kummer et al. [J. Acoust. Soc. Am. 103, 3431-3444 (1998)] at f2 frequencies of 2000 and 4000 Hz. Interpretable SFOAE responses were obtained from 1000-6000 Hz in the equal-level paradigm. SFOAE levels were larger than DPOAEs levels, signal-to-noise ratios were smaller, and I/O functions were less compressive. A two-slope model of SFOAE I/O functions predicted the low-level round-trip attenuation, the breakpoint between linearity and compression, and compressive slope. In ear but not coupler recordings, the noise at the SFOAE frequency increased with increasing level (above 60 dB SPL), whereas noise at adjacent frequencies did not. This suggests the existence of a source of signal-dependent noise producing cochlear variability, which is predicted to influence basilar-membrane motion and neural responses. A repeatable pattern of notched SFOAE I/O functions was present in some ears, and explained using a two-source mechanism of SFOAE generation.

Entities:  

Mesh:

Year:  2003        PMID: 12942975     DOI: 10.1121/1.1592799

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  33 in total

1.  Stimulus-frequency otoacoustic emissions measured with amplitude-modulated suppressor tones (L).

Authors:  Stephen T Neely; Tiffany A Johnson; Cassie A Garner; Michael P Gorga
Journal:  J Acoust Soc Am       Date:  2005-10       Impact factor: 1.840

2.  Simultaneous measurement of noise-activated middle-ear muscle reflex and stimulus frequency otoacoustic emissions.

Authors:  Shawn S Goodman; Douglas H Keefe
Journal:  J Assoc Res Otolaryngol       Date:  2006-03-28

3.  Use of stimulus-frequency otoacoustic emission latency and level to investigate cochlear mechanics in human ears.

Authors:  Kim S Schairer; John C Ellison; Denis Fitzpatrick; Douglas H Keefe
Journal:  J Acoust Soc Am       Date:  2006-08       Impact factor: 1.840

4.  Testing coherent reflection in chinchilla: Auditory-nerve responses predict stimulus-frequency emissions.

Authors:  Christopher A Shera; Arnold Tubis; Carrick L Talmadge
Journal:  J Acoust Soc Am       Date:  2008-07       Impact factor: 1.840

5.  Use of stimulus-frequency otoacoustic emissions to investigate efferent and cochlear contributions to temporal overshoot.

Authors:  Douglas H Keefe; Kim S Schairer; John C Ellison; Denis F Fitzpatrick; Walt Jesteadt
Journal:  J Acoust Soc Am       Date:  2009-03       Impact factor: 1.840

6.  Measuring stimulus-frequency otoacoustic emissions using swept tones.

Authors:  Radha Kalluri; Christopher A Shera
Journal:  J Acoust Soc Am       Date:  2013-07       Impact factor: 1.840

7.  Influence of stimulus parameters on amplitude-modulated stimulus frequency otoacoustic emissions.

Authors:  Tiffany A Johnson; Laura Beshaler
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

8.  Stimulus-frequency otoacoustic emission suppression tuning in humans: comparison to behavioral tuning.

Authors:  Karolina K Charaziak; Pamela Souza; Jonathan H Siegel
Journal:  J Assoc Res Otolaryngol       Date:  2013-09-07

9.  High frequency transient-evoked otoacoustic emission measurements using chirp and click stimuli.

Authors:  Douglas H Keefe; M Patrick Feeney; Lisa L Hunter; Denis F Fitzpatrick; Chelsea M Blankenship; Angela C Garinis; Daniel B Putterman; Marcin Wróblewski
Journal:  Hear Res       Date:  2018-10-18       Impact factor: 3.208

10.  Two-tone suppression of stimulus frequency otoacoustic emissions.

Authors:  Douglas H Keefe; John C Ellison; Denis F Fitzpatrick; Michael P Gorga
Journal:  J Acoust Soc Am       Date:  2008-03       Impact factor: 1.840

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.