Literature DB >> 12941509

EPR dosimetric properties of formates.

Tor Arne Vestad1, Eirik Malinen, Anders Lund, Eli Olaug Hole, Einar Sagstuen.   

Abstract

As a part of a program to develop an electron paramagnetic resonance (EPR) dosimeter suited for clinical use (doses in the cGy range), polycrystalline samples of lithium formate monohydrate (HCO2Li.H2O), magnesium formate dihydrate (C2H2O4Mg.2H2O), and calcium formate (C2H2O4Ca) have been examined. L-Alanine was included for comparison and reference. Samples were irradiated with 60Co gamma-rays and 60-220 kV X-rays. The dosimeter response was assessed using the peak-to-peak amplitude of the first-derivative EPR spectrum. Dose-response curves for the 60Co gamma-irradiated samples were constructed, and the dependences of the response on the photon energy, microwave power, and modulation amplitude were studied. Stability of the irradiation products upon storage (signal fading) was also investigated. Lithium formate monohydrate is by far the best candidate of the tested formates, suitable for measuring doses down to approximately 0.1 Gy. Lithium formate monohydrate is more sensitive than alanine by a factor of 5.6-6.8 in the tested photon energy range, it exhibits no zero-dose signal and shows a linear dose response in the dose range from 0.2 to 1000 Gy. Its EPR signal was found unchanged in shape and intensity 1 week after irradiation to 10 Gy. Various less favorable properties rendered the other formates generally unsuitable, although calcium formate exhibits some interesting EPR dosimetric properties.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12941509     DOI: 10.1016/s0969-8043(03)00165-9

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  4 in total

1.  Dosimetric and kinetic investigations of γ-irradiated sodium tartrate dihydrate.

Authors:  H Tuner; M A Kayikçi
Journal:  Radiat Environ Biophys       Date:  2011-11-04       Impact factor: 1.925

Review 2.  Clinical applications of alanine/electron spin resonance dosimetry.

Authors:  Oswaldo Baffa; Angela Kinoshita
Journal:  Radiat Environ Biophys       Date:  2014-01-08       Impact factor: 1.925

3.  Monte Carlo Calculation of Beam Quality and Phantom Scatter Corrections for Lithium Formate Electron Paramagnetic Resonance Dosimeter for High-energy Brachytherapy Dosimetry.

Authors:  Subhalaxmi Mishra; T Palani Selvam
Journal:  J Med Phys       Date:  2017 Apr-Jun

4.  Controlled synthesis of Bi- and tri-nuclear Cu-oxo nanoclusters on metal-organic frameworks and the structure-reactivity correlations.

Authors:  Qi Xue; Bryan Kit Yue Ng; Ho Wing Man; Tai-Sing Wu; Yun-Liang Soo; Molly Mengjung Li; Shogo Kawaguchi; Kwok Yin Wong; Shik Chi Edman Tsang; Bolong Huang; Tsz Woon Benedict Lo
Journal:  Chem Sci       Date:  2021-11-29       Impact factor: 9.825

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.