Literature DB >> 12938125

Fat suppression strategies in enhanced MR imaging of the breast: comparison of SPIR and water excitation sequences.

Mamoru Niitsu1, Eriko Tohno, Yuji Itai.   

Abstract

PURPOSE: To compare two fat suppression techniques of spectrally-selective inversion pulse (spectral presaturation with inversion recovery-SPIR) and spectral-spatial excitation pulse of water excitation (WE) for contrast-enhanced MR imaging of the breast.
MATERIALS AND METHODS: Forty women with histologically-proven breast cancer were examined. Both pulse types were applied to postcontrast, axial, three-dimensional field echo sequence. Contrast noise ratios (CNR) of lesion-to-breast parenchyma, lesion-to-fat, and parenchyma-to-fat were determined. Qualitative image analysis using a four-point scale was also performed by two observers.
RESULTS: All the CNR values of obtained with WE techniques were significantly higher than those with SPIR. Qualitative analysis indicated that the WE images were statistically superior for the lesion-to-breast parenchyma contrast while being slightly inferior to the SPIR images for fat suppression homogeneity without statistical significance.
CONCLUSION: Compared to SPIR, the WE technique suppressed the subcutaneous fat signal more potently and improved the contrast of the enhanced breast lesion against the parenchyma and the subcutaneous fat. WE will be a powerful fat suppression strategy for enhanced MR imaging of the breast. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12938125     DOI: 10.1002/jmri.10364

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Contrast-enhanced MR myelography in spontaneous intracranial hypotension: description of an artefact imitating CSF leakage.

Authors:  Elke Hattingen; Richard DuMesnil; Ulrich Pilatus; Andreas Raabe; Timo Kahles; Jürgen Beck
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

2.  Fat suppression strategies in MR imaging of breast cancer at 3.0 T: comparison of the two-point Dixon technique and the frequency selective inversion method.

Authors:  Wakako Kaneko Mikami; Toshiki Kazama; Hirotaka Sato; Hajime Yokota; Takashi Higashide; Takuro Horikoshi; Ken Motoori; Yukimasa Miyazawa; Takeshi Nagashima; Takashi Uno
Journal:  Jpn J Radiol       Date:  2013-06-24       Impact factor: 2.374

3.  Comparison of breast tissue measurements using magnetic resonance imaging, digital mammography and a mathematical algorithm.

Authors:  Lee-Jane W Lu; Thomas K Nishino; Raleigh F Johnson; Fatima Nayeem; Donald G Brunder; Hyunsu Ju; Morton H Leonard; James J Grady; Tuenchit Khamapirad
Journal:  Phys Med Biol       Date:  2012-10-09       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.