Literature DB >> 12937201

Inflammatory potential of dust from schools and building related symptoms.

L Allermann1, H W Meyer, O M Poulsen, J B Nielsen, F Gyntelberg.   

Abstract

AIMS: To test whether the inflammatory potential of dust samples might be used to differentiate schools with high and low prevalence of building related symptoms (BRS) among the occupants.
METHODS: Ten schools with high prevalence of BRS and 10 schools with low prevalence were selected. Dust collected from floors, horizontal surfaces, and exhaust outlets was tested at five concentrations on the lung epithelial cell line A549. The potency of the dust (PF) to stimulate IL-8 secretion was calculated from the initial linear part of the dose-response curves. The organic fraction of the dust samples was determined by incineration.
RESULTS: The schools with low prevalence of symptoms had a BRS% of 4.4-11.0 and the schools with high prevalence a BRS% of 19.6-31.9. The PF of floor dust and surface dust correlated, and the PF was associated with the organic content of the dust. The schools with low prevalence of symptoms had a significantly lower PF than the schools with high prevalence. Using the cut point value of 4.5 ng IL-8/mg floor dust, significantly more high prevalence schools were found above the cut point than below.
CONCLUSION: The PF of the floor dust samples correlated significantly with the prevalence of symptoms in the schools. The content of endotoxin and microorganisms did not seem to explain the inflammatory potential of the dust or BRS, and the substances in the dust causing the inflammatory potential are presently unknown.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12937201      PMCID: PMC1740613          DOI: 10.1136/oem.60.9.e5

Source DB:  PubMed          Journal:  Occup Environ Med        ISSN: 1351-0711            Impact factor:   4.402


  9 in total

Review 1.  Sick building syndrome.

Authors:  M Hodgson
Journal:  Occup Med       Date:  2000 Jul-Sep

2.  Inflammatory potential of dust from waste handling facilities measured as IL-8 secretion from lung epithelial cells in vitro.

Authors:  L Allermann; O M Poulsen
Journal:  Ann Occup Hyg       Date:  2000-06

Review 3.  (1-->3)-beta-D-glucan - relationship to indoor air-related symptoms, allergy and asthma.

Authors:  R Rylander; R H Lin
Journal:  Toxicology       Date:  2000-11-02       Impact factor: 4.221

Review 4.  Sick-building syndrome.

Authors:  C A Redlich; J Sparer; M R Cullen
Journal:  Lancet       Date:  1997-04-05       Impact factor: 79.321

Review 5.  Possible mechanisms for the respiratory tract effects of noncarcinogenic indoor-climate pollutants and bases for their risk assessment.

Authors:  G Damgård Nielsen; Y Alarie; O Melchior Poulsen; B Andersen Nexø
Journal:  Scand J Work Environ Health       Date:  1995-06       Impact factor: 5.024

6.  Airway epithelial cells and mediators of inflammation.

Authors:  J L Devalia; R J Davies
Journal:  Respir Med       Date:  1993-08       Impact factor: 3.415

7.  Symptoms and mechanisms--inflammation of the lung.

Authors:  R Rylander
Journal:  Am J Ind Med       Date:  1994-01       Impact factor: 2.214

Review 8.  Interactions between respiratory epithelial cells and cytokines: relationships to lung inflammation.

Authors:  K B Adler; B M Fischer; D T Wright; L A Cohn; S Becker
Journal:  Ann N Y Acad Sci       Date:  1994-05-28       Impact factor: 5.691

9.  Airborne gram-negative bacteria and endotoxin in sick building syndrome. A study in Dutch governmental office buildings.

Authors:  K B Teeuw; C M Vandenbroucke-Grauls; J Verhoef
Journal:  Arch Intern Med       Date:  1994-10-24
  9 in total
  2 in total

1.  Dust weight and asthma prevalence in the National Survey of Lead and Allergens in Housing (NSLAH).

Authors:  Leslie Elliott; Samuel J Arbes; Eric S Harvey; Robert C Lee; Päivi M Salo; Richard D Cohn; Stephanie J London; Darryl C Zeldin
Journal:  Environ Health Perspect       Date:  2006-11-07       Impact factor: 9.031

2.  Differential response of Mono Mac 6, BEAS-2B, and Jurkat cells to indoor dust.

Authors:  Herbert Riechelmann; Tom Deutschle; Ariane Grabow; Birger Heinzow; Werner Butte; Rudolf Reiter
Journal:  Environ Health Perspect       Date:  2007-09       Impact factor: 9.031

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.