Literature DB >> 12931322

SPECT/CT in tumor imaging: technical aspects and clinical applications.

Zohar Keidar1, Ora Israel, Yodphat Krausz.   

Abstract

Diagnostic imaging has gained a major role in the management of patients with cancer and has made a further step forward with the introduction of fusion techniques into the field. This technology provides hybrid images of two independent modalities, a functional scintigraphic technique and an anatomical procedure, yielding a superior imaging study. Scintigraphy is based on the use of single photon or positron emitting tracers providing a description of function or processes, whereas computed tomography (CT), ultrasound, or magnetic resonance imaging (MRI) depict the precise localization and type of morphological changes that have occurred in the lesions. Initial attempts to coregister the functional and anatomical information following acquisition of the two imaging modalities on separate machines, in different sessions, failed to disclose the proper alignment with precise coregistration, in particular for non-head studies, and were associated with patient preparation and mathematical modeling that were too cumbersome to be used on a routine basis. The recent introduction of a hybrid imaging device containing a low dose CT system and a gamma camera on a single gantry enabled the sequential acquisition of the two imaging modalities, with subsequent merging of data into a composite image display. These hybrid studies have led to a revolution in the field of imaging, with highly accurate localization of tumor sites, assessment of invasion into surrounding tissues, and characterization of their functional status. Copyright 2003 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2003        PMID: 12931322     DOI: 10.1053/snuc.2003.127310

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  46 in total

1.  Monoclonal immunoscintigraphy for detection of metastasis and recurrence of colorectal cancer.

Authors:  Vera Artiko; Ana Koljevic Marković; Dragana Sobić-Šaranović; Milorad Petrović; Andrija Antić; Mirjana Stojković; Marinko Zuvela; Djordjije Saranović; Milica Stojković; Nebojša Radovanović; Danijel Galun; Aleksandar Milovanović; Jovica Milovanović; Anica Bobić-Radovanović; Zoran Krivokapic; Vladimir Obradović
Journal:  World J Gastroenterol       Date:  2011-05-21       Impact factor: 5.742

2.  Impact of indium-111 oxine labelling on viability of human mesenchymal stem cells in vitro, and 3D cell-tracking using SPECT/CT in vivo.

Authors:  Franz Josef Gildehaus; Florian Haasters; Inga Drosse; Erika Wagner; Christian Zach; Wolf Mutschler; Paul Cumming; Peter Bartenstein; Matthias Schieker
Journal:  Mol Imaging Biol       Date:  2011-12       Impact factor: 3.488

3.  [Combined Scanners (PET/CT, SPECT/CT) Versus Multimodality Imaging with Separated Systems].

Authors:  T Pfluger; C la Fougère; J Stauss; R Santos; C Vollmar; K Hahn
Journal:  Radiologe       Date:  2004-11       Impact factor: 0.635

4.  Hybrid SPECT/CT: a new era for SPECT imaging?

Authors:  Orazio Schillaci
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05       Impact factor: 9.236

5.  67Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma.

Authors:  Barbara Palumbo; Silvio Sivolella; Isabella Palumbo; Anna Marina Liberati; Renato Palumbo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-14       Impact factor: 9.236

Review 6.  Primer on molecular imaging technology.

Authors:  Craig S Levin
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-12       Impact factor: 9.236

7.  Dual-isotope acquisition for CT-SPECT registration of infection studies.

Authors:  Lisa Tang; Ghassan Hamarneh; Anna Celler
Journal:  J Digit Imaging       Date:  2009-01-10       Impact factor: 4.056

8.  The yield of SPECT/CT for anatomical lymphatic mapping in patients with breast cancer.

Authors:  Iris M C van der Ploeg; Omgo E Nieweg; Bin B R Kroon; Emiel J T Rutgers; Marie-Jeanne T F D Baas-Vrancken Peeters; Wouter V Vogel; Cornelis A Hoefnagel; Renato A Valdés Olmos
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-13       Impact factor: 9.236

9.  EANM-EORTC general recommendations for sentinel node diagnostics in melanoma.

Authors:  Annette H Chakera; Birger Hesse; Zeynep Burak; James R Ballinger; Allan Britten; Corrado Caracò; Alistair J Cochran; Martin G Cook; Krzysztof T Drzewiecki; Richard Essner; Einat Even-Sapir; Alexander M M Eggermont; Tanja Gmeiner Stopar; Christian Ingvar; Martin C Mihm; Stanley W McCarthy; Nicola Mozzillo; Omgo E Nieweg; Richard A Scolyer; Hans Starz; John F Thompson; Giuseppe Trifirò; Giuseppe Viale; Sergi Vidal-Sicart; Roger Uren; Wendy Waddington; Arturo Chiti; Alain Spatz; Alessandro Testori
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-10       Impact factor: 9.236

10.  Comparison of Single-Photon Emission Computed Tomography-Computed Tomography (SPECT/CT) and Conventional Planar Lymphoscintigraphy for Sentinel Node Localization in Patients with Cutaneous Malignancies.

Authors:  Matthew P Doepker; Maki Yamamoto; Matthew A Applebaum; Nupur U Patel; M Jaime Montilla-Soler; Amod A Sarnaik; C Wayne Cruse; Vernon K Sondak; Jonathan S Zager
Journal:  Ann Surg Oncol       Date:  2016-09-22       Impact factor: 5.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.