Literature DB >> 12928089

Measuring esophageal distention by high-frequency intraluminal ultrasound probe.

Ravinder K Mittal1.   

Abstract

This investigation used a high-frequency intraluminal ultrasound (HFIUS) probe to study changes in esophageal muscle thickness as a marker of muscle contraction. The aim of this study was to determine whether this technique could accurately measure distention of the esophagus during swallows of liquid bolus and during gastroesophageal reflux (GER) in normal subjects. Despite some limitations, HFIUS appears to be a valid technique for both of these measurements in normal subjects. Future studies in patients with symptomatic GER disease (GERD) should be able to determine whether typical symptoms such as heartburn, as well as atypical symptoms such as chest pain, are related to the GER-related distention of the esophagus.

Entities:  

Mesh:

Year:  2003        PMID: 12928089     DOI: 10.1016/s0002-9343(03)00211-0

Source DB:  PubMed          Journal:  Am J Med        ISSN: 0002-9343            Impact factor:   4.965


  7 in total

1.  Determinants of perception of heartburn and regurgitation.

Authors:  A J Bredenoord; B L A M Weusten; W L Curvers; R Timmer; A J P M Smout
Journal:  Gut       Date:  2005-08-24       Impact factor: 23.059

2.  Transcutaneous cervical esophagus ultrasound in adults: relation with ambulatory 24-h pH-monitoring and esophageal manometry.

Authors:  Sabite Kacar; Selma Uysal; Sedef Kuran; Ulku Dagli; Yasemin Ozin; Erdem Karabulut; Nurgul Sasmaz
Journal:  World J Gastroenterol       Date:  2007-10-21       Impact factor: 5.742

3.  Weakly acidic reflux in patients with chronic unexplained cough during 24 hour pressure, pH, and impedance monitoring.

Authors:  D Sifrim; L Dupont; K Blondeau; X Zhang; J Tack; J Janssens
Journal:  Gut       Date:  2005-04       Impact factor: 23.059

Review 4.  Advances in motility testing--current and novel approaches.

Authors:  Albert J Bredenoord; André J P M Smout
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2013-05-07       Impact factor: 46.802

5.  Sonographic measurement of abdominal esophageal length as a diagnostic tool in gastroesophageal reflux disease in infants.

Authors:  Hamid Dehdashti; Masoud Dehdashtian; Fakher Rahim; Mehrdad Payvasteh
Journal:  Saudi J Gastroenterol       Date:  2011 Jan-Feb       Impact factor: 2.485

6.  Dimensions and circumferential stress-strain relation in the porcine esophagus in vitro determined by combined impedance planimetry and high-frequency ultrasound.

Authors:  Jingbo Zhao; Claus S Jørgensen; Donghua Liao; Hans Gregersen
Journal:  Dig Dis Sci       Date:  2007-03-14       Impact factor: 3.487

7.  A catheter-based acoustic interrogation device for monitoring motility dynamics of the lower esophageal sphincter.

Authors:  Qian Lu; Orly Yadid-Pecht; Daniel C Sadowski; Martin P Mintchev
Journal:  Sensors (Basel)       Date:  2014-08-12       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.