Literature DB >> 12928026

Improving feasibility of posterior descending coronary artery flow recording by transthoracic Doppler echocardiography.

A Auriti1, C Cianfrocca, C Pristipino, S Greco, M Galeazzi, V Guido, M Santini.   

Abstract

AIMS: Recording coronary arteries' flow by transthoracic Doppler echocardiography (TTDE) is a new task. Despite several studies concerning the left anterior descending artery (LAD) exist, the same for posterior descending coronary artery (PD) do not. Reported feasibility is not more than 76%. The aim of the study was to try to improve feasibility by using an additional two-dimensional view as a guide. METHODS AND
RESULTS: PD flow recording was performed in 35 consecutive unselected patients under the guidance of the usual two-dimensional modified view [a two-chamber view (2-C)], and with a new four-chamber modified view (4-C). A semi-quantitative growing-quality score (from 0 to 3 points) to the trace was given. Contrast enhancement was used if PD was not visualized without it. The overall feasibility was 80%. A good or very good velocity signal (TTDE score > or = 2) was observed in 48% of patients without contrast enhancement. Time for first visualization of PD was short and significantly lower in 2-C than in 4-C (66 +/- 39 vs 90 +/- 70 s, respectively, P<0.05).
CONCLUSIONS: TTDE recording of PD flow gained better feasibility being guided by two views. Maximal time for first visualization of PD was less than 3 min.

Entities:  

Mesh:

Year:  2003        PMID: 12928026     DOI: 10.1016/s1525-2167(03)00014-3

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  3 in total

1.  Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression.

Authors:  Juan M Jiménez; Varesh Prasad; Michael D Yu; Christopher P Kampmeyer; Abdul-Hadi Kaakour; Pei-Jiang Wang; Sean F Maloney; Nathan Wright; Ian Johnston; Yi-Zhou Jiang; Peter F Davies
Journal:  J R Soc Interface       Date:  2014-02-19       Impact factor: 4.118

2.  Hemodynamically driven stent strut design.

Authors:  Juan M Jiménez; Peter F Davies
Journal:  Ann Biomed Eng       Date:  2009-05-27       Impact factor: 3.934

3.  Distal left circumflex coronary artery flow reserve recorded by transthoracic Doppler echocardiography: a comparison with Doppler-wire.

Authors:  Antonio Auriti; Christian Pristipino; Cinzia Cianfrocca; Antonino Granatelli; Vincenzo Guido; Francesco Pelliccia; Salvatore Greco; Giuseppe Richichi; Massimo Santini
Journal:  Cardiovasc Ultrasound       Date:  2007-06-16       Impact factor: 2.062

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.