Literature DB >> 12924766

Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt.

Toshiaki Ueno1, Richard E Ballard, Brandon R Macias, William T Yost, Alan R Hargens.   

Abstract

INTRODUCTION: Intracranial pressure (ICP) may play a significant role in physiological responses to microgravity by contributing to the nausea associated with microgravity exposure. However, effects of altered gravity on ICP in astronauts have not been investigated, primarily due to the invasiveness of currently available techniques. We have developed an ultrasonic device that monitors changes in cranial diameter pulsation non-invasively so that we can evaluate ICP dynamics in astronauts during spaceflight. This study was designed to demonstrate the feasibility of our ultrasound technique under the physiological condition in which ICP dynamics are changed due to altered gravitational force.
METHODS: Six healthy volunteers were placed at 60 degrees head-up, 30 degrees headup, supine, and 15 degrees head-down positions for 3 min at each angle. We measured arterial blood pressure (ABP) with a finger pressure cuff, and cranial diameter pulsation with a pulsed phase lock loop device (PPLL).
RESULTS: Analysis of covariance demonstrated that amplitudes of cranial diameter pulsations were significantly altered with the angle of tilt (p < 0.001). The 95% confidence interval for linear regression coefficients of the cranial diameter pulsation amplitudes with tilt angle was 0.862 to 0.968. However, ABP amplitudes did not show this relationship. DISCUSSION: Our noninvasive ultrasonic technique reveals that the amplitude of cranial diameter pulsation decreases as a function of tilt angle, suggesting that ICP pulsation follows the same relationship. It is demonstrated that the PPLL device has a sufficient sensitivity to detect changes non-invasively in ICP pulsation caused by altered gravity.

Entities:  

Keywords:  NASA Discipline Cardiopulmonary; NASA Program Biomedical Research and Countermeasures; Non-NASA Center

Mesh:

Year:  2003        PMID: 12924766

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  5 in total

1.  Could intracranial pressure in traumatic brain injury be measured or predicted noninvasively? Almost.

Authors:  Nino Stocchetti
Journal:  Intensive Care Med       Date:  2007-08-01       Impact factor: 17.440

2.  Anterior-posterior transcranial ultrasound to measure cranial oscillations.

Authors:  John H K Liu; John E Lynch; Armando Rosales-Velderrain; Douglas G Chang; Robert N Weinreb; Alan R Hargens
Journal:  Aviat Space Environ Med       Date:  2013-09

3.  A simple nonmydriatic self-retinal imaging procedure using a Kowa Genesis-D hand-held digital fundus camera.

Authors:  Ugur Ozerdem
Journal:  Ophthalmic Res       Date:  2009-07-01       Impact factor: 2.892

4.  Lower-body negative pressure decreases noninvasively measured intracranial pressure and internal jugular vein cross-sectional area during head-down tilt.

Authors:  William Watkins; Alan R Hargens; Shannon Seidl; Erika Marie Clary; Brandon R Macias
Journal:  J Appl Physiol (1985)       Date:  2017-05-11

5.  Assessment of calvarial structure motion by MRI.

Authors:  William T Crow; Hollis H King; Rita M Patterson; Vincent Giuliano
Journal:  Osteopath Med Prim Care       Date:  2009-09-04
  5 in total