Literature DB >> 12923323

Nitric oxide metabolites, eosinophils, and eosinophilic cationic protein in patients with asthma: sputum versus blood.

An-Soo Jang1, Chung-Ho Yeum, In-Seon Choi.   

Abstract

The monitoring of airway inflammation has assessed in bronchial asthma directly by sputum examination, and indirectly by measurements in peripheral blood. To investigate the diagnostic value of these two methods, we compared nitric oxide (NO) metabolites, eosinophils, and eosinophil cationic protein (ECP) in sputum and blood in patients with asthma and control subjects. Sputum and serum were obtained from fifteen patients with asthma, and then were examined before anti-asthma treatment, including steroid preparations. ECP was measured by fluoroimmunoassay. NO metabolites were assayed by using modified Griess reaction. Asthmatic patients, compared with control subjects, had significantly higher level of NO metabolites, higher proportion of eosinophils, and higher levels of ECP in sputum. Asthmatic patients, compared with control subjects, however, had significantly higher number of eosinophils, and were at higher levels of ECP in blood. FEV1, FEV1/FVC was negatively correlated with sputum eosinophils. The area under receiver operating characteristic (ROC) curve showed that eosinophils in sputum are significantly accurate markers than NO metabolites in sputum and blood. These findings suggest that the proportion of eosinophils in sputum have more accurate diagnostic marker of asthmatic airway inflammation than NO metabolites in sputum in differentiating asthmatic patients from control subjects.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12923323      PMCID: PMC3055074          DOI: 10.3346/jkms.2003.18.4.489

Source DB:  PubMed          Journal:  J Korean Med Sci        ISSN: 1011-8934            Impact factor:   2.153


  2 in total

1.  Effect of different monotherapies on serum nitric oxide and pulmonary functions in children with mild persistent asthma.

Authors:  Zeinab Mohamed Radwan; Gamal Abdel Nasser Yamamah; Hala Hamdy Shaaban; Azza Mohamed Omar Abdel-Rahman; Amany Abdel-Ghany Ismaeil; Elham Mohamed Mostafa
Journal:  Arch Med Sci       Date:  2010-12-29       Impact factor: 3.318

2.  The predictive value of eosinophil cationic protein and lactate dehydrogenase in asthma: a comparative study of serum versus sputum.

Authors:  Amina Hamed Ahmad Al Obaidi; Abdul Ghani Mohamed Al Samarai; Jasim Al-Janabi; Abdulkareem Yahia
Journal:  World Allergy Organ J       Date:  2009-07       Impact factor: 4.084

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.