Literature DB >> 12920549

[New ceramic materials for use in anophthalmia surgery].

P Y Robert1, J Rulfi, J P Adenis.   

Abstract

Over the last 20 years eyeball replacement surgery has improved, especially with the widely accepted use of biocolonisable implants. These implants allow long-lasting biointegration, thus improving prosthesis motility and reducing the rate of postoperative exposure. In this article, we review the chemical structure, toxicity data and manufacturing procedures of the three main commercially available materials: aluminium, hydroxyapatite and porous polyethylene.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12920549     DOI: 10.1007/s00347-003-0848-5

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  17 in total

1.  A buried muscle cone implant. Development of a tunneled hemispherical type.

Authors:  J H ALLEN; L ALLEN
Journal:  Arch Ophthal       Date:  1950-05

2.  Dermis-fat graft as a movable implant within the muscle cone.

Authors:  B Smith; R Petrelli
Journal:  Am J Ophthalmol       Date:  1978-01       Impact factor: 5.258

3.  [Total anthroplasty of the hip with aluminum prostheses].

Authors:  P Boutin
Journal:  Acta Orthop Belg       Date:  1974       Impact factor: 0.500

4.  A preliminary report on the Universal Implant.

Authors:  D R Jordan; R L Anderson; J A Nerad; L Allen
Journal:  Arch Ophthalmol       Date:  1987-12

5.  [Prevention of postenucleation syndrome: the hydroxylapatite silicone implant. Preliminary experimental studies and initial clinical experiences].

Authors:  R Guthoff; H P Vick; U Schaudig
Journal:  Ophthalmologe       Date:  1995-04       Impact factor: 1.059

6.  High-density porous polyethylene (Medpor) as a successful anophthalmic socket implant.

Authors:  J W Karesh; S C Dresner
Journal:  Ophthalmology       Date:  1994-10       Impact factor: 12.079

7.  An autogenous kinetic dermis-fat orbital implant: an updated technique.

Authors:  B Smith; S L Bosniak; R D Lisman
Journal:  Ophthalmology       Date:  1982-09       Impact factor: 12.079

8.  [Alumina and its use in surgery of the hip. (Experimental study)].

Authors:  P Boutin
Journal:  Presse Med       Date:  1971-03-20       Impact factor: 1.228

9.  Use of GORE-TEX (polytetrafluoroethylene) in the anophthalmic socket.

Authors:  S Morax
Journal:  Adv Ophthalmic Plast Reconstr Surg       Date:  1990

10.  Baseball orbital implants: a review of 39 patients.

Authors:  A G Tyers; J R Collin
Journal:  Br J Ophthalmol       Date:  1985-06       Impact factor: 4.638

View more
  2 in total

1.  [Anophthalmia and microphthalmia].

Authors:  R F Guthoff
Journal:  Ophthalmologe       Date:  2003-07       Impact factor: 1.059