Literature DB >> 12919759

A randomized, prospective clinical trial to assess the potential infection risk associated with the PosiFlow needleless connector.

A L Casey1, T Worthington, P A Lambert, D Quinn, M H Faroqui, T S J Elliott.   

Abstract

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12919759     DOI: 10.1016/s0195-6701(03)00130-0

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  12 in total

1.  Impact of a multidimensional infection control strategy on central line-associated bloodstream infection rates in pediatric intensive care units of five developing countries: findings of the International Nosocomial Infection Control Consortium (INICC).

Authors:  V D Rosenthal; B Ramachandran; W Villamil-Gómez; A Armas-Ruiz; J A Navoa-Ng; L Matta-Cortés; M Pawar; A Nevzat-Yalcin; M Rodríguez-Ferrer; R D Yıldızdaş; A Menco; R Campuzano; V D Villanueva; L F Rendon-Campo; A Gupta; O Turhan; N Barahona-Guzmán; O O Horoz; P Arrieta; J M Brito; M C V Tolentino; Y Astudillo; N Saini; N Gunay; G Sarmiento-Villa; E Gumus; A Lagares-Guzmán; O Dursun
Journal:  Infection       Date:  2012-02-28       Impact factor: 3.553

2.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-04-01       Impact factor: 9.079

3.  epic3: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England.

Authors:  H P Loveday; J A Wilson; R J Pratt; M Golsorkhi; A Tingle; A Bak; J Browne; J Prieto; M Wilcox
Journal:  J Hosp Infect       Date:  2014-01       Impact factor: 3.926

4.  epic2: National evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England.

Authors:  R J Pratt; C M Pellowe; J A Wilson; H P Loveday; P J Harper; S R L J Jones; C McDougall; M H Wilcox
Journal:  J Hosp Infect       Date:  2007-02       Impact factor: 3.926

5.  Clean technique for prolonged nonsurvival cardiothoracic surgery in swine (Sus scrofa).

Authors:  Maia M Chan; David G Rabkin; Ida M Washington
Journal:  J Am Assoc Lab Anim Sci       Date:  2013-01       Impact factor: 1.232

6.  Consistency between guidelines and reported practice for reducing the risk of catheter-related infection in British paediatric intensive care units.

Authors:  Katie Harron; Geethanjali Ramachandra; Quen Mok; Ruth Gilbert
Journal:  Intensive Care Med       Date:  2011-08-30       Impact factor: 17.440

Review 7.  Skin antisepsis for reducing central venous catheter-related infections.

Authors:  Nai Ming Lai; Nai An Lai; Elizabeth O'Riordan; Nathorn Chaiyakunapruk; Jacqueline E Taylor; Kenneth Tan
Journal:  Cochrane Database Syst Rev       Date:  2016-07-13

Review 8.  Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review.

Authors:  Nancy L Moureau; Julie Flynn
Journal:  Nurs Res Pract       Date:  2015-05-14

9.  Closed catheter access system implementation in reducing the bloodstream infection rate in low birth weight preterm infants.

Authors:  Lily Rundjan; Rinawati Rohsiswatmo; Tiara Nien Paramita; Chrissela Anindita Oeswadi
Journal:  Front Pediatr       Date:  2015-03-16       Impact factor: 3.418

10.  How much is red blood cell fragmentation increased by the use of closed luer lock access devices on catheter hubs?

Authors:  Sunny Eloot; Jean-Yves De Vos; Remi Hombrouckx
Journal:  NDT Plus       Date:  2008-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.