OBJECTIVES: To demonstrate reliability and feasibility of a standardized protocol to assess and score quality indicators relevant to pressure ulcer (PU) care processes in nursing homes (NHs).
DESIGN: Descriptive.
SETTING: Eight NHs. PARTICIPANTS: One hundred ninety-one NH residents for whom the PU Resident Assessment Protocol of the Minimum Data Set was initiated. MEASUREMENTS: Nine quality indicators (two related to screening and prevention of PU, two focused on assessment, and five addressing management) were scored using medical record data, direct human observation, and wireless thigh monitor observation data. Feasibility and reliability of medical record, observation, and thigh monitor protocols were determined.
RESULTS: The percentage of participants who passed each of the indicators, indicating care consistent with practice guidelines, ranged from 0% to 98% across all indicators. In general, participants in NHs passed fewer indicators and had more problems with medical record accuracy before a PU was detected (screening/prevention indicators) than they did once an ulcer was documented (assessment and management indicators). Reliability of the medical record protocol showed kappa statistics ranging from 0.689 to 1.00 and percentage agreement from 80% to 100%. Direct observation protocols yielded kappa statistics of 0.979 and 0.928. Thigh monitor protocols showed kappa statistics ranging from 0.609 to 0.842. Training was variable, with the observation protocol requiring 1 to 2 hours, medical records requiring joint review of 20 charts with average time to complete the review of 20 minutes, and the thigh monitor data requiring 1 week for training in data preparation and interpretation.
CONCLUSION: The standardized quality assessment system generated scores for nine PU quality indicators with good reliability and provided explicit scoring rules that permit reproducible conclusions about PU care. The focus of the indicators on care processes that are under the control of NH staff made the protocol useful for external survey and internal quality improvement purposes, and the thigh monitor observational technology provided a method for monitoring repositioning care processes that were otherwise difficult to monitor and manage.

Entities:  

Mesh:

Year:  2003        PMID: 12919230     DOI: 10.1046/j.1532-5415.2003.51402.x

Source DB:  PubMed          Journal:  J Am Geriatr Soc        ISSN: 0002-8614            Impact factor:   5.562


  6 in total

1.  Quality indicators for in-hospital pharmaceutical care of Dutch elderly patients: development and validation of an ACOVE-based quality indicator set.

Authors:  Peter C Wierenga; Joanna E Klopotowska; Susanne M Smorenburg; Hendrikus J van Kan; Yuma A Bijleveld; Marcel G Dijkgraaf; Sophia E de Rooij
Journal:  Drugs Aging       Date:  2011-04-01       Impact factor: 3.923

2.  Predictors of nonpharmacological and pharmacological treatments stopped and started among nursing home residents with dementia.

Authors:  Michelle R Simpson; Christine R Kovach; Frank Stetzer
Journal:  Res Gerontol Nurs       Date:  2011-09-16       Impact factor: 1.571

3.  Frequent manual repositioning and incidence of pressure ulcers among bed-bound elderly hip fracture patients.

Authors:  Shayna E Rich; David Margolis; Michelle Shardell; William G Hawkes; Ram R Miller; Sania Amr; Mona Baumgarten
Journal:  Wound Repair Regen       Date:  2010-12-06       Impact factor: 3.617

Review 4.  Assessing quality of care of elderly patients using the ACOVE quality indicator set: a systematic review.

Authors:  Marjan Askari; Peter C Wierenga; Saied Eslami; Stephanie Medlock; Sophia E de Rooij; Ameen Abu-Hanna
Journal:  PLoS One       Date:  2011-12-16       Impact factor: 3.240

5.  A Survey of Basic Daily Living Assistance in Dependency Units during the Morning First Period at Nursing Homes with a Healthcare Dysfunction.

Authors:  José Antonio Camacho-Conde; David Juan Muñoz-Arbona
Journal:  Nurs Rep       Date:  2022-02-14

6.  Measurement of bed turning and comparison with age, gender, and body mass index in a healthy population: application of a novel mobility detection system.

Authors:  Shang-Lin Chiang; Chia-Huei Lin; Shin-Tsu Chang; Chueh-Ho Lin; Po-Yin Chen; Wen-Hsu Sung; Shun-Hwa Wei
Journal:  Biomed Res Int       Date:  2014-04-29       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.