Literature DB >> 12918981

Screening of inhibitors using enzymes entrapped in sol-gel-derived materials.

Travis R Besanger1, Yang Chen, Anil K Deisingh, Richard Hodgson, Wen Jin, Stanislas Mayer, Michael A Brook, John D Brennan.   

Abstract

In recent years, a number of new methods have been reported that make use of immobilized enzymes either on microarrays or in bioaffinity columns for high-throughput screening of compound libraries. A key question that arises in such methods is whether immobilization may alter the intrinsic catalytic and inhibition constants of the enzyme. Herein, we examine how immobilization within sol-gel-derived materials affects the catalytic constant (kcat), Michaelis constant (KM), and inhibition constant (KI) of the clinically relevant enzymes Factor Xa, dihydrofolate reductase, cyclooxygenase-2, and gamma-glutamyl transpeptidase. These enzymes were encapsulated into sol-gel-derived glasses produced from either tetraethyl orthosilicate (TEOS) or the newly developed silica precursor diglyceryl silane (DGS). It was found that the catalytic efficiency and long-term stability of all enzymes were improved upon entrapment into DGS-derived materials relative to entrapment in TEOS-based glasses, likely owing to the liberation of the biocompatible reagent glycerol from DGS. The KM values of enzymes entrapped in DGS-derived materials were typically higher than those in solution, whereas upon entrapment, kcat values were generally lowered by a factor of 1.5-7 relative to the value in solution, indicating that substrate turnover was limited by partitioning effects or diffusion through the silica matrix. Nonetheless, the apparent KI value for the entrapped enzyme was in most cases within error of the value in solution, and even in the worst case, the values differed by no more than a factor of 3. The implications of these findings for high-throughput screening are discussed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918981     DOI: 10.1021/ac026370i

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

Review 1.  Common causes of glucose oxidase instability in in vivo biosensing: a brief review.

Authors:  James M Harris; Catherine Reyes; Gabriel P Lopez
Journal:  J Diabetes Sci Technol       Date:  2013-07-01

2.  Tyrosine phenol-lyase and tryptophan indole-lyase encapsulated in wet nanoporous silica gels: Selective stabilization of tertiary conformations.

Authors:  Barbara Pioselli; Stefano Bettati; Tatyana V Demidkina; Lyudmila N Zakomirdina; Robert S Phillips; Andrea Mozzarelli
Journal:  Protein Sci       Date:  2004-04       Impact factor: 6.725

3.  Engineering the Turnover Stability of Cellobiose Dehydrogenase toward Long-Term Bioelectronic Applications.

Authors:  Andreas F Geiss; Thomas M B Reichhart; Barbara Pejker; Esther Plattner; Peter L Herzog; Christopher Schulz; Roland Ludwig; Alfons K G Felice; Dietmar Haltrich
Journal:  ACS Sustain Chem Eng       Date:  2021-05-12       Impact factor: 9.224

Review 4.  Current Trends in Nanomaterial-Based Amperometric Biosensors.

Authors:  Akhtar Hayat; Gaëlle Catanante; Jean Louis Marty
Journal:  Sensors (Basel)       Date:  2014-12-08       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.