Literature DB >> 12918968

Fluorescence multiplexing with time-resolved and spectral discrimination using a near-IR detector.

Li Zhu1, Wieslaw Stryjewski, Suzanne Lassiter, Steven A Soper.   

Abstract

We report on the design and performance of a two-color, time-resolved detector for the acquisition of both steady-state and time-resolved fluorescence data acquired in real time during the capillary gel electrophoresis separation of DNA sequencing fragments. The detector consisted of a pair of pulsed laser diodes operating at 680 and 780 nm. The diode heads were coupled directly to single-mode fibers, which were terminated into a single fiber mounted via a FC/PC connector to the detector body. The detector contained a dichroic filter, which directed the dual-laser beams to an objective. The objective focused the laser light into a capillary gel column and also collected the resulting fluorescence emission. The dual-color emission was transmitted through the dichroic and focused onto a multimode fiber (core diameter 50 microm), which carried the luminescence to a pair of single-photon avalanche diodes (SPADs). The emission was sorted spectrally using a second dichroic onto one of two SPADs and isolated using appropriate interference filters (710- or 810-nm channel). The dual-color detector demonstrated a time response of 450 and 510 ps (fwhm) for the 710- and 810-nm channels, respectively. The mass detection limits for two near-IR dye-labeled sequencing primers electrophoresed in a capillary gel column were found to be 7.1 x 10(-21) and 3.2 x 10(-20) mol (SNR = 3) for the 710- and 810-nm detector channels, respectively. In addition, no leakage of luminescence excited at 680 nm was observed in the 810-nm channel or 780-nm excited luminescence into the 710-nm channel. An M13mp18 template was sequenced in a single capillary gel column using a two-color, two-lifetime format. The read length was found to be 650 base pairs for the test template at a calling accuracy of 95.1% using a linear poly(dimethylacrylamide) (POP6) gel column, with the read length determined primarily by the electrophoretic resolution produced by the sieving gel.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918968     DOI: 10.1021/ac020776d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Color-blind fluorescence detection for four-color DNA sequencing.

Authors:  Ernest K Lewis; Wade C Haaland; Freddy Nguyen; Daniel A Heller; Matthew J Allen; Robert R MacGregor; C Scott Berger; Britain Willingham; Lori A Burns; Graham B I Scott; Carter Kittrell; Bruce R Johnson; Robert F Curl; Michael L Metzker
Journal:  Proc Natl Acad Sci U S A       Date:  2005-03-30       Impact factor: 11.205

2.  Solid-phase synthesis of asymmetrically substituted "AB3-type" phthalocyanines.

Authors:  S Sibel Erdem; Irina V Nesterova; Steven A Soper; Robert P Hammer
Journal:  J Org Chem       Date:  2008-05-30       Impact factor: 4.354

3.  Metallo-phthalocyanine near-IR fluorophores: oligonucleotide conjugates and their applications in PCR assays.

Authors:  Irina V Nesterova; Vera T Verdree; Serhii Pakhomov; Karen L Strickler; Michael W Allen; Robert P Hammer; Steven A Soper
Journal:  Bioconjug Chem       Date:  2007-11-21       Impact factor: 4.774

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.