Literature DB >> 12918593

Functions for detecting malposition of transcutaneous energy transmission coils.

Toshinaga Ozeki1, Tsuneo Chinzei, Yusuke Abe, Itsuro Saito, Takashi Isoyama, Shuuichi Mochizuki, Mitsuhiko Ishimaru, Koki Takiura, Atsushi Baba, Takahiro Toyama, Kou Imachi.   

Abstract

A transcutaneous energy transmission system (TETS) for artificial hearts and ventricular assist devices uses electrical coupling of power between external and implanted coils. If the position of coils changes relative to each other, the TETS cannot feed the required power of the implanted device. During activity or sleep, the coils may move accidentally. TETS users and the people around them have to pay attention to this because the range of the position where the required power can be fed efficiently is not wide. Therefore, we added functions for the position changes of the coils to the TETS. Regular, cautious, and irregular positions were introduced, and the ranges of them were decided upon in our experiments. The cautious position was determined by the area where the change of the relative position of the coils was relatively small. When the coils were in the cautious position, the circuit was tuned by way of changing the resonant point. This modulation could give good power efficiency in the cautious position. When the coils were in the irregular position, an alarm switch was turned on. These functions ease the restriction of the coil position and give better quality of life (QOL) than do the conventional TETS.

Entities:  

Mesh:

Year:  2003        PMID: 12918593

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Analysis of specific absorption rate and internal electric field in human biological tissues surrounding an air-core coil-type transcutaneous energy transmission transformer.

Authors:  Kenji Shiba; Nur Elina Binti Zulkifli; Yuji Ishioka
Journal:  J Artif Organs       Date:  2016-11-21       Impact factor: 1.731

2.  In vivo demonstration of a self-sustaining, implantable, stimulated-muscle-powered piezoelectric generator prototype.

Authors:  B E Lewandowski; K L Kilgore; K J Gustafson
Journal:  Ann Biomed Eng       Date:  2009-08-06       Impact factor: 3.934

3.  Conformal phased surfaces for wireless powering of bioelectronic microdevices.

Authors:  Devansh R Agrawal; Yuji Tanabe; Desen Weng; Andrew Ma; Stephanie Hsu; Song-Yan Liao; Zhe Zhen; Zi-Yi Zhu; Chuanbowen Sun; Zhenya Dong; Fengyuan Yang; Hung Fat Tse; Ada S Y Poon; John S Ho
Journal:  Nat Biomed Eng       Date:  2017-03-06       Impact factor: 25.671

  3 in total