Literature DB >> 12918553

Enucleation: is wrapping the implant necessary for optimal motility?

John A Long1, Thomas M Tann, William H Bearden, Michael A Callahan.   

Abstract

PURPOSE: To compare the mobility of wrapped and unwrapped hydroxyapatite orbital implants after enucleation.
METHODS: Fifteen consecutive adult patients underwent enucleation with hydroxyapatite implant placement. These patients randomly received either a wrapped or unwrapped implant. A masked observer measured the motility of implants at 6 weeks after implantation. The conjunctiva was marked and measured with a ruler. These measurements were used to compare the motility of the wrapped versus unwrapped implant.
RESULTS: The mean elevation for the wrapped group (n = 7) was 4 mm and for the unwrapped group (n = 8) was 3.9 mm. Depression was 4.1 mm for the wrapped group and 3.6 mm for the unwrapped group. Medial excursions were 5.3 for the wrapped group and 5.0 mm for the unwrapped group. Lateral excursions were 3.7 mm for the wrapped group and 3.5 mm for the unwrapped group. A repeated-measures analysis of variance was performed, and no statistically significant difference was found between the two groups.
CONCLUSIONS: We conclude that placement of unwrapped hydroxyapatite implants after enucleation provides essentially the same motility as wrapped implants. This technique also saves time and money and eliminates the possibility of infectious disease transmission from donor wrapping materials.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918553     DOI: 10.1097/01.iop.0000066647.77902.0b

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  3 in total

Review 1.  Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

Authors:  Silvana Schellini; Regina El Dib; Leandro Re Silva; Joyce G Farat; Yuqing Zhang; Eliane C Jorge
Journal:  Cochrane Database Syst Rev       Date:  2016-11-07

2.  UK national survey of enucleation, evisceration and orbital implant trends.

Authors:  P Viswanathan; Mandeep S Sagoo; Jane M Olver
Journal:  Br J Ophthalmol       Date:  2006-12-06       Impact factor: 4.638

3.  Enucleation and evisceration at a tertiary care hospital in a developing country.

Authors:  Osama H Ababneh; Eman A AboTaleb; Mohammad A Abu Ameerh; Yacoub A Yousef
Journal:  BMC Ophthalmol       Date:  2015-09-11       Impact factor: 2.209

  3 in total