Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants.

Yonca Ozkan Arat1, Debra J Shetlar, Milton Boniuk.   

Abstract

PURPOSE: To report our experience with bovine pericardium as a wrapping material for hydroxyapatite orbital implants after enucleation and to compare the exposure rates of the implants wrapped with bovine pericardium versus donor sclera.
METHODS: We retrospectively reviewed the records of all patients who received bovine pericardium-wrapped or donor sclera-wrapped hydroxyapatite implant after primary enucleation between March 1995 and December 2001.
RESULTS: Of the 26 patients who received donor sclera-wrapped implants after enucleation, 1 (3.8%) had implant exposure. Of the 26 patients who received bovine pericardium-wrapped implants after enucleation, 6 (23%) had implant exposure. The incidence of implant exposure with the use bovine pericardium wrapping material was found to be significantly higher than with sclera (P = 0.05). Six of the 7 implant exposures were noted in the first 6 months after placement of the orbital implant. Five of the 6 exposed bovine pericardium-wrapped hydroxyapatite implants were associated with socket infection. The case of exposure of the sclera-wrapped implant was treated conservatively by observation. Six patients who had exposure of bovine pericardium-wrapped implants required multiple repairs because of recurrent exposures. Four of these patients eventually required removal of the implant.
CONCLUSIONS: Despite the advantages of using bovine pericardium as a wrapping material for hydroxyapatite orbital implants, we observed a significantly higher incidence of exposure with bovine pericardium compared with donor sclera in the early postoperative period. Use of bovine pericardium as a wrapping material for orbital implants should be avoided unless some future modifications of the technique can be developed to prevent such complications.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918552     DOI: 10.1097/01.iop.0000062850.71572.7d

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  3 in total

1.  Complications due to bovine pericardium used to cover acrylic implants after enucleation and tubes of aqueous devices.

Authors:  F R De Vries; I C Notting; M Marinkovic; N E Schalij-Delfos; G P M Luyten
Journal:  Eye (Lond)       Date:  2011-11-11       Impact factor: 3.775

2.  Comparative study of modified and conventional secondary hydroxyapatite orbital implantations.

Authors:  Yong Zhao; Mao-Nian Zhang; Yun-Xian Gao; Xiao-Wei Gao; Bing Ren
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

Review 3.  Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

Authors:  Silvana Schellini; Regina El Dib; Leandro Re Silva; Joyce G Farat; Yuqing Zhang; Eliane C Jorge