Literature DB >> 12917128

Retrograde flow in the left inferior petrosal sinus and blood steal of the cavernous sinus associated with central vein stenosis: MR angiographic findings.

Yahya Paksoy1, Bülent Oğuz Genç, Emine Genç.   

Abstract

BACKGROUND AND
PURPOSE: We attempted to identify the cause of abnormal venous flow seen during arterial MR angiography in the inferior petrosal sinus by use of in three female patients (aged 51, 48, and 70 years, respectively).
METHODS: Arterial 3D time-of-flight MR angiography was performed with a tilted optimized nonsaturating excitation pulse sequence (TR/TE, 31/7; flip angle, 20 degrees; section thickness, 65 mm; effective thickness, 1 mm; number of sections, 1 to 2); no magnetization transfer pulse sequence was used. Contrast-enhanced 3D MR angiography of the neck was performed with a 3D fast low-angle shot pulse sequence (TR/TE, 4.6/1.8; flip angle, 40 to 45 degrees; section thickness, 80 mm; intersection gap, 1.5 mm; acquisition matrix, 180 x 256; acquisition time, 27 s) on a system with a whole-body coil.
RESULTS: In all three patients, 3D time-of-flight MR angiography revealed abnormal vascular signal originating from the left cavernous sinus, continuing through the inferior petrosal sinus, and ending in the proximal internal jugular vein at the jugular bulb level. Abnormal vascular signal at the jugular bulb, sluggish flow and flow-related enhancement in the left internal jugular vein, and signal void in the contralateral jugular vein were noted. Contrast-enhanced delayed-phase MR angiography showed stenosis in the left brachiocephalic vein in all patients.
CONCLUSION: High signal intensity noted at the inferior petrosal sinus resulted from retrograde flow. Retrograde flow was due to blood stealing from the internal jugular vein toward the cavernous sinus because of venous stenosis in the brachiocephalic vein.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12917128      PMCID: PMC7973675     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  6 in total

1.  Diagnosis of carotid-cavernous fistulas with magnetic resonance angiography--demonstrating the draining veins utilizing 3-D time-of-flight and 3-D phase-contrast techniques.

Authors:  F Ikawa; T Uozumi; K Kiya; K Kurisu; K Arita; M Sumida
Journal:  Neurosurg Rev       Date:  1996       Impact factor: 3.042

2.  Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: comparison with contrast-enhanced CT and spin-echo MR.

Authors:  T Hirai; Y Korogi; S Hamatake; I Ikushima; T Sugahara; Y Sigematsu; Y Higashida; M Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  1998-02       Impact factor: 3.825

3.  Cavernous sinus and inferior petrosal sinus flow signal on three-dimensional time-of-flight MR angiography.

Authors:  S Ouanounou; T A Tomsick; C Heitsman; C K Holland
Journal:  AJNR Am J Neuroradiol       Date:  1999-09       Impact factor: 3.825

4.  MR imaging of the cavernous sinus: value of spin echo and gradient recalled echo images.

Authors:  D L Daniels; L F Czervionke; J F Bonneville; F Cattin; L P Mark; P Pech; L E Hendrix; D F Smith; V M Haughton; A L Williams
Journal:  AJR Am J Roentgenol       Date:  1988-11       Impact factor: 3.959

5.  Suspected dural arteriovenous fistula: results with screening MR angiography in seven patients.

Authors:  J C Chen; J S Tsuruda; V V Halbach
Journal:  Radiology       Date:  1992-04       Impact factor: 11.105

6.  Follow-up MRI in dural arteriovenous malformations involving the cavernous sinus: emphasis on detection of venous thrombosis.

Authors:  N Hirabuki; N Fujita; T Hashimoto; K Fujii; T Miura; M Mitomo; R Kawai; T Kozuka
Journal:  Neuroradiology       Date:  1992       Impact factor: 2.804

  6 in total
  16 in total

1.  Physiologic change in flow velocity and direction of dural venous sinuses with respiration: MR venography and flow analysis.

Authors:  Kohsuke Kudo; Satoshi Terae; Aki Ishii; Tokuhiko Omatsu; Takeshi Asano; Khin Khin Tha; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

2.  Susceptibility-weighted imaging in carotido-cavernous fistulas. A case control study.

Authors:  Kamble Jayaprakash Harsha; Ram Shenoy Basti; Chandrasekharan Kesavadas; Bejoy Thomas
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

3.  Assessment of dural arteriovenous fistulas of the cavernous sinuses on 3D dynamic MR angiography.

Authors:  H Akiba; M Tamakawa; H Hyodoh; K Hyodoh; N Yama; T Nonaka; Y Minamida; M Hashimoto; M Hareyama
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-26       Impact factor: 3.825

4.  Evaluation of dural arteriovenous fistulas of cavernous sinus before and after endovascular treatment using time-resolved MR angiography.

Authors:  Shigeyuki Sakamoto; Masaaki Shibukawa; Yoshihiro Kiura; Toshinori Matsushige; Nobukazu Abe; Kaoru Kurisu
Journal:  Neurosurg Rev       Date:  2010-02-25       Impact factor: 3.042

5.  Obstruction of Venous Drainage Linked to Transient Global Amnesia.

Authors:  Ke Han; A-Ching Chao; Feng-Chi Chang; Chih-Ping Chung; Hung-Yi Hsu; Wen-Yung Sheng; Jiang Wu; Han-Hwa Hu
Journal:  PLoS One       Date:  2015-07-14       Impact factor: 3.240

6.  Quantitative Measurements of Cerebral Circulation in Spontaneously Regressing Traumatic Carotid-Cavernous Sinus Fistula with Velocity-Encoded Magnetic Resonance Imaging.

Authors:  Ho Kyun Kim; Sung Won Youn; Jongmin Lee
Journal:  Clin Neuroradiol       Date:  2014-04-10       Impact factor: 3.649

7.  The effects of perturbed cerebral blood flow and cerebrovascular reactivity on structural MRI and behavioral readouts in mild traumatic brain injury.

Authors:  Justin A Long; Lora T Watts; Wei Li; Qiang Shen; Eric R Muir; Shiliang Huang; Robert C Boggs; Abhinav Suri; Timothy Q Duong
Journal:  J Cereb Blood Flow Metab       Date:  2015-06-24       Impact factor: 6.200

8.  Normal flow signal of the pterygoid plexus on 3T MRA in patients without DAVF of the cavernous sinus.

Authors:  K Watanabe; S Kakeda; R Watanabe; N Ohnari; Y Korogi
Journal:  AJNR Am J Neuroradiol       Date:  2012-12-28       Impact factor: 3.825

9.  Evaluation of dural arteriovenous fistulas with 4D contrast-enhanced MR angiography at 3T.

Authors:  S Nishimura; T Hirai; A Sasao; M Kitajima; M Morioka; Y Kai; Y Omori; T Okuda; R Murakami; H Fukuoka; K Awai; J-I Kuratsu; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-15       Impact factor: 3.825

10.  Reflux venous flow in dural sinus and internal jugular vein on 3D time-of-flight MR angiography.

Authors:  Jinhee Jang; Bum-Soo Kim; Bom-Yi Kim; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Jae Young Byun
Journal:  Neuroradiology       Date:  2013-07-19       Impact factor: 2.804

View more