Literature DB >> 12909439

Measuring range of active cervical rotation in a position of full head flexion using the 3D Fastrak measurement system: an intra-tester reliability study.

M Amiri1, G Jull, J Bullock-Saxton.   

Abstract

Most external assessments of cervical range of motion assess the upper and lower cervical regions simultaneously. This study investigated the within and between days reliability of the clinical method used to bias this movement to the upper cervical region, namely measuring rotation of the head and neck in a position of full cervical flexion. Measurements were made using the Fastrak measurement system and were conducted by one operator. Results indicated high levels of within and between days repeatability (range of ICC2,1 values: 0.85-0.95). The ranges of axial rotation to right and left, measured with the neck positioned in full flexion, were approximately 56% and 50%, respectively of total cervical rotation, which relates well to the proportional division of rotation in the upper and lower cervical regions. These results suggest that this method of measuring rotation would be appropriate for use in subject studies where movement dysfunction is present in the upper cervical region, such as those with cervicogenic headache.

Entities:  

Mesh:

Year:  2003        PMID: 12909439     DOI: 10.1016/s1356-689x(03)00009-2

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  13 in total

1.  The C0-C2 axial rotation test: normal values, intra- and inter-rater reliability and correlation with the flexion rotation test in normal subjects.

Authors:  Kiran Satpute; Sadaf Nalband; Toby Hall
Journal:  J Man Manip Ther       Date:  2018-10-12

2.  The flexion-rotation test performed actively and passively: a comparison of range of motion in patients with cervicogenic headache.

Authors:  Shannon M Bravo Petersen; Vassilios G Vardaxis
Journal:  J Man Manip Ther       Date:  2015-05

3.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

Authors:  Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti
Journal:  BMC Musculoskelet Disord       Date:  2010-08-31       Impact factor: 2.362

4.  Irregular head movement patterns in whiplash patients during a trajectory task.

Authors:  Astrid Woodhouse; Øyvind Stavdahl; Ottar Vasseljen
Journal:  Exp Brain Res       Date:  2009-10-10       Impact factor: 1.972

5.  Clinical evaluation of cervicogenic headache: a clinical perspective.

Authors:  Toby Hall; Kathy Briffa; Diana Hopper
Journal:  J Man Manip Ther       Date:  2008

6.  Effects of tailored neck-shoulder pain treatment based on a decision model guided by clinical assessments and standardized functional tests. A study protocol of a randomized controlled trial.

Authors:  Martin Björklund; Mats Djupsjöbacka; Asa Svedmark; Charlotte Häger
Journal:  BMC Musculoskelet Disord       Date:  2012-05-20       Impact factor: 2.362

7.  A technical support tool for joint range of motion determination in functional diagnostics - an inter-rater study.

Authors:  Christoph Schiefer; Thomas Kraus; Rolf P Ellegast; Elke Ochsmann
Journal:  J Occup Med Toxicol       Date:  2015-04-29       Impact factor: 2.646

Review 8.  Methods for evaluating cervical range of motion in trauma settings.

Authors:  Sarah Voss; Michael Page; Jonathan Benger
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-08-02       Impact factor: 2.953

9.  Altered motor control patterns in whiplash and chronic neck pain.

Authors:  Astrid Woodhouse; Ottar Vasseljen
Journal:  BMC Musculoskelet Disord       Date:  2008-06-20       Impact factor: 2.362

Review 10.  Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review.

Authors:  Chantal H P de Koning; Sylvia P van den Heuvel; J Bart Staal; Bouwien C M Smits-Engelsman; Erik J M Hendriks
Journal:  Eur Spine J       Date:  2008-04-22       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.