Literature DB >> 12909110

Time and space patterns of volatile organic compounds in a sewage treatment plant.

A Escalas1, J M Guadayol, M Cortina, J Rivera, J Caixach.   

Abstract

47 regulated and non-regulated volatile organic compounds (VOCs) were characterised by closed-loop stripping analysis (CLSA) and high resolution gas chromatography coupled to mass spectrometry (HRGC/MS) in 28 aqueous samples from 4 sampling points along a sewage treatment plant in Manresa, Catalonia, Spain. A 4 x 2(2) factorial design (16 samples) was first prepared for the sampling, and reinforced with 12 additional samples at the plant influent. The total analyte weighted mean concentration was 232 microg x l(-1) at the plant influent, with a mass flow of 2231 kg x yr(-1). Petroleum solvents and terpenic compounds accounted for 79% of the influent analyte concentration. VOC concentration in influent was clearly higher for most VOCs from 12 to 22 h (high organic load hours), and lower from 24 to 10 h (lower organic load). Differences between time bands were confirmed through t tests. Differences between weekdays and the weekend were not so clear, and could not be confirmed through t tests. VOC concentrations along the plant are discussed. Overall analyte removal in the plant was 89%.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12909110     DOI: 10.1016/S0043-1354(03)00336-1

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  4 in total

1.  HS-SPME/GC-MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge.

Authors:  Urszula Kotowska; Maciej Żalikowski; Valery A Isidorov
Journal:  Environ Monit Assess       Date:  2011-06-18       Impact factor: 2.513

2.  Gas Phase Toluene Adsorption Using Date Palm-Tree Branches Based Activated Carbon.

Authors:  Muhammad Vohra; Mohammad Al-Suwaiyan; Minaam Hussaini
Journal:  Int J Environ Res Public Health       Date:  2020-12-11       Impact factor: 3.390

3.  Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants.

Authors:  Jacek Gebicki; Hubert Byliński; Jacek Namieśnik
Journal:  Environ Monit Assess       Date:  2015-12-15       Impact factor: 2.513

4.  Distribution Characteristics of Volatile Organic Compounds and Contribution to Ozone Formation in a Coking Wastewater Treatment Plant.

Authors:  Yuxiu Zhang; Tingting Zang; Bo Yan; Chaohai Wei
Journal:  Int J Environ Res Public Health       Date:  2020-01-15       Impact factor: 3.390

  4 in total