Literature DB >> 12908954

A validated HPLC method for the assay of xanthone and 3-methoxyxanthone in PLGA nanocapsules.

Maribel Teixeira1, Carlos M M Afonso, Madalena M M M Pinto, Carlos Maurício Barbosa.   

Abstract

This work relates the development and validation of a simple reversed-phase high-performance liquid chromatographic (HPLC) method for the analysis of xanthone (XAN) and 3-methoxyxanthone (3-MeOXAN) in poly(D,L-lactide-co-glycolide) (PLGA) nanocapsule formulations. This method does not require any complex sample extraction procedure. Chromatographic separation is made with a reversed-phase C(18) column, using methanol-water (90:10, v/v) as a mobile phase at a flow rate of 1 mL/min. Identification is made by UV detection at 237 nm. The isocratic system operates at ambient temperature and requires 7 min of chromatographic time. The developed method is statistically validated according to United States Pharmacopoeia 25 and International Conference on Harmonization guidelines for its specificity, linearity, accuracy, and precision. The assay method proposed in this study is specific for XAN and 3-MeOXAN in the presence of nanocapsule excipients. Diode-array analyses confirm the homogeneity of XAN and 3-MeOXAN peaks in stressed conditions. Standard curves are linear (r > 0.999) over the concentration range of 0.4-2.5 and 1.0-5.8 micro g/mL for XAN and 3-MeOXAN, respectively. Recovery from nanocapsules ranges from 99.6% to 102.8% for XAN and 98.8% to 102.4% for 3-MeOXAN. Repeatability (intra-assay precision) is acceptable with relative standard deviation values of 1.2% for XAN and 0.3% for 3-MeOXAN.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12908954     DOI: 10.1093/chromsci/41.7.371

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  2 in total

Review 1.  From Natural Products to New Synthetic Small Molecules: A Journey through the World of Xanthones.

Authors:  Madalena M M Pinto; Andreia Palmeira; Carla Fernandes; Diana I S P Resende; Emília Sousa; Honorina Cidade; Maria Elizabeth Tiritan; Marta Correia-da-Silva; Sara Cravo
Journal:  Molecules       Date:  2021-01-15       Impact factor: 4.411

2.  Development and validation of an RP-HPLC method for CB13 evaluation in several PLGA nanoparticle systems.

Authors:  J Alvarez-Fuentes; L Martín-Banderas; I Muñoz-Rubio; M A Holgado; M Fernández-Arévalo
Journal:  ScientificWorldJournal       Date:  2012-06-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.