Literature DB >> 12902947

Partial disc replacement with the PDN prosthetic disc nucleus device: early clinical results.

Chan Shik Shim1, Sang Ho Lee, Cheul Woong Park, Won Chul Choi, Gun Choi, Won Gyu Choi, Sang Rak Lim, Ho Yeon Lee.   

Abstract

The aim of this study was to evaluate the efficacy of the PDN prosthetic disc nucleus device for the treatment of chronic discogenic back pain caused by degenerative disc disease. Among the 48 patients who underwent nucleus replacement surgery from January 2001 through May 2002, 46 patients were followed >6 months. The mean Oswestry Disability Index score was 58.9% preoperatively, and it improved to 18% at the 1-year follow-up. Visual Analogue Pain Scale scores improved from a preoperative mean of 8.5 to 3.1 after 1 year. The mean Prolo Scale score also improved from 5.2 preoperatively to 7.2 at 1 year. Major complications included four cases of device migration, requiring revision surgery, and infection in one patient. According to MacNab's criteria, results were excellent in 5 patients (10.9%), good in 31 (67.4%), fair in 3 (6.5%), and poor in 7 (15.1%). The overall clinical success rate was 78.3%. Nucleus replacement with the PDN device seemed to be effective in treating patients with chronic discogenic back pain caused by degenerative disc disease.

Entities:  

Mesh:

Year:  2003        PMID: 12902947     DOI: 10.1097/00024720-200308000-00003

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  6 in total

1.  Injectable silk fibroin/polyurethane composite hydrogel for nucleus pulposus replacement.

Authors:  Jingen Hu; Bin Chen; Fang Guo; Jingyu Du; Pengcheng Gu; Xiangjin Lin; Weiping Yang; Hailong Zhang; Min Lu; Yiping Huang; Gewen Xu
Journal:  J Mater Sci Mater Med       Date:  2012-01-10       Impact factor: 3.896

2.  Long-term outcome after implantation of prosthetic disc nucleus device (PDN) in lumbar disc disease.

Authors:  P Selviaridis; N Foroglou; A Tsitlakidis; A Hatzisotiriou; I Magras; I Patsalas
Journal:  Hippokratia       Date:  2010-07       Impact factor: 0.471

3.  Screening for nuclear replacement candidates in patients with lumbar degenerative disc disease.

Authors:  Ioannis Pappou; Frank Cammisa; Elias Papadopoulos; Peter Frelinghuysen; Federico Girardi
Journal:  SAS J       Date:  2008-06-01

4.  Biomechanical assessment and fatigue characteristics of an articulating nucleus implant.

Authors:  Nathaniel R Ordway; William F Lavelle; Tim Brown; Q-Bin Bao
Journal:  Int J Spine Surg       Date:  2013-12-01

5.  Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement.

Authors:  Jingen Hu; Yang Lu; Ling Cai; Kwabena Gyabaah Owusu-Ansah; Gewen Xu; Feilong Han; Junjie Bao; Xiangjin Lin; Yiping Huang
Journal:  Sci Rep       Date:  2017-05-24       Impact factor: 4.379

6.  Finite Element Analysis of a Bionate Ring-Shaped Customized Lumbar Disc Nucleus Prosthesis.

Authors:  Amparo Vanaclocha-Saiz; Vicente Vanaclocha; Carlos M Atienza; Pablo Clavel; Pablo Jorda-Gomez; Carlos Barrios; Leyre Vanaclocha
Journal:  ACS Appl Bio Mater       Date:  2021-12-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.