Literature DB >> 12900613

Reliable assessment of skin flap viability using orthogonal polarization imaging.

Wendy-Ann M Olivier1, Alexes Hazen, Jamie P Levine, Hooman Soltanian, Seum Chung, Geoffrey C Gurtner.   

Abstract

Intraoperative evaluation of skin flap viability has primarily been dependent on clinical judgment. The purpose of this study was to determine whether an orthogonal polarization spectral imaging device could be used to accurately predict viability of random-pattern skin flaps. Orthogonal polarization spectral imaging is a newly developed technique that visualizes the microcirculation using reflected light without the use of fluorescent dyes and allows for noninvasive real-time observation of functional microvascular networks. In Sprague-Dawley rats (n = 24), three types of random skin flaps were designed with unknown zones of viability (n = 8 per group). After flap elevation, the skin flaps were evaluated by both clinical examination and orthogonal polarization spectral imaging. Areas of the flap determined to be nonviable by clinical examination were measured and marked. Orthogonal polarization spectral imaging was subsequently performed, and areas of the skin flap with stasis (i.e., cessation of red blood cell movement) in the dermal microcirculation on orthogonal polarization spectral imaging were measured and marked. The skin flaps were then secured in place. Flaps were evaluated on a daily basis for clinical signs of ischemia and necrosis. On postoperative day 7, the total amount of random skin flap necrosis was measured and recorded. Clinical examination of the random skin flaps significantly underestimated the actual amount of eventual flap necrosis, and as result was a very poor predictor of flap necrosis. By contrast, assessment of microcirculatory stasis using the orthogonal polarization spectral imaging device correlated well with the subsequent development of necrosis in all groups. In the three groups, the average amount of flap necrosis predicted by clinical examination deviated from actual necrosis by approximately 2 to 4 cm. However, the amount that orthogonal polarization spectral imaging differed from actual necrosis was 0.1 to 0.3 cm. Therefore, orthogonal polarization spectral imaging was an excellent predictor of eventual flap necrosis and much more accurate than clinical observation (p < 0.001). Intraoperative evaluation of axial and random pattern flap viability has traditionally been based on clinical examination as no other reliable, convenient test currently exists. The authors demonstrated that an orthogonal polarization spectral imaging device accurately predicts zones of necrosis in random pattern flaps by directly visualizing cessation of microcirculatory flow. Intraoperative stasis in the dermal microcirculation correlated precisely with subsequent flap necrosis. Orthogonal polarization spectral imaging was significantly more accurate than clinical examination, which consistently underestimated flap necrosis. The orthogonal polarization spectral imaging technique may have value in the intraoperative assessment of skin flap perfusion such as that required after skin-sparing mastectomy.

Entities:  

Mesh:

Year:  2003        PMID: 12900613     DOI: 10.1097/01.PRS.0000070968.42857.43

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  8 in total

1.  An evaluation of five different dressing materials on split-thickness skin graft donor site and full-thickness cutaneous wounds: an experimental study.

Authors:  Muhammet Uraloğlu; Murat Livaoğlu; Özgür Agdoğan; Sevdegül Mungan; Etem Alhan; Naci Karaçal
Journal:  Int Wound J       Date:  2012-09-03       Impact factor: 3.315

2.  The use of indocyanine green angiography to prevent wound complications in ventral hernia repair with open components separation technique.

Authors:  H D Wang; D P Singh
Journal:  Hernia       Date:  2012-06-20       Impact factor: 4.739

3.  Synergistic interactions with a high intraoperative expander fill volume increase the risk for mastectomy flap necrosis.

Authors:  Nima Khavanin; Sumanas Jordan; Francis Lovecchio; Neil A Fine; John Kim
Journal:  J Breast Cancer       Date:  2013-12-31       Impact factor: 3.588

Review 4.  Mastectomy skin flap necrosis: challenges and solutions.

Authors:  Stuart A Robertson; Johann A Jeevaratnam; Avi Agrawal; Ramsey I Cutress
Journal:  Breast Cancer (Dove Med Press)       Date:  2017-03-13

5.  Effects of buflomedil and pentoxifylline on hamster skin-flap microcirculation: prediction of flap viability using orthogonal polarization spectral imaging.

Authors:  Denise Salles Coelho da Mota; Eliane Furtado; Daniel Alexandre Bottino; Eliete Bouskela
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

6.  Intraoperative laser angiography using the SPY system: review of the literature and recommendations for use.

Authors:  Geoffrey C Gurtner; Glyn E Jones; Peter C Neligan; Martin I Newman; Brett T Phillips; Justin M Sacks; Michael R Zenn
Journal:  Ann Surg Innov Res       Date:  2013-01-07

7.  Potential of the SPY intraoperative perfusion assessment system to reduce ischemic complications in immediate postmastectomy breast reconstruction.

Authors:  Mohit Sood; Paul Glat
Journal:  Ann Surg Innov Res       Date:  2013-07-23

8.  A Prospective Study of Immediate Breast Reconstruction with Laser-Assisted Indocyanine Green Angiography.

Authors:  Shayda J Mirhaidari; Gregory M Beddell; Marc V Orlando; Michael G Parker; John C Pedersen; Douglas S Wagner
Journal:  Plast Reconstr Surg Glob Open       Date:  2018-09-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.