Literature DB >> 12898119

Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell.

Daniel Pröfrock1, Peter Leonhard, Andreas Prange.   

Abstract

The determination of sulfur in biologically relevant samples such as metalloproteins is described. The analytical methodology used is based on robust on-line coupling between capillary electrophoresis (CE) and octopole reaction cell inductively-coupled plasma mass spectrometry (ORC-ICP-MS). Polyatomic ions that form in the plasma and interfere with the determination of S at mass 32 are minimised by addition of xenon to the collision cell. The method has been applied to the separation and simultaneous element-specific detection of sulfur, cadmium, copper, and zinc in commercially available metallothionein preparations (MT) and metallothionein-like proteins (MLP) extracted from liver samples of bream ( Abramis brama L.) caught in the river Elbe, Germany. Instrumental detection limits have been calculated according to the German standard procedure DIN 32645 for the determination of sulfur and some simultaneously measured trace elements in aqueous solution. For sulfur detection limits down to 1.3 microg L(-1) ((34)S) and 3.2 microg L(-1) ((32)S) were derived. For the other trace elements determined simultaneously detection limits ranging from 300 ng L(-1) ((58)Ni) to 500 ng L(-1) ((66)Zn, (55)Mn) were achieved. For quantification of sulfur and cadmium in a commercially available MT preparation under hyphenated conditions the use of external calibration is suggested. Finally, the need for proper sample-preparation technique will be discussed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12898119     DOI: 10.1007/s00216-003-2041-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Cobalt complexes as internal standards for capillary zone electrophoresis-mass spectrometry studies in biological inorganic chemistry.

Authors:  Hannah U Holtkamp; Stuart J Morrow; Mario Kubanik; Christian G Hartinger
Journal:  J Biol Inorg Chem       Date:  2017-01-02       Impact factor: 3.358

2.  The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements.

Authors:  Ondrej Hanousek; Marion Brunner; Daniel Pröfrock; Johanna Irrgeher; Thomas Prohaska
Journal:  Anal Methods       Date:  2016-09-23       Impact factor: 2.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.