Literature DB >> 12897494

Influence of cage geometry on sagittal alignment in instrumented posterior lumbar interbody fusion.

Stefan Gödde1, Ekkehard Fritsch, Michael Dienst, Dieter Kohn.   

Abstract

STUDY
DESIGN: Retrospective radiographic evaluation of the sagittal alignment of the lumbar spine in patients undergoing short-segment instrumented posterior lumbar interbody fusion with cage systems of different shape.
OBJECTIVES: To determine whether rectangular and wedge-shaped cages have a different influence on the sagittal alignment of the lumbar spine in patients undergoing short-segment instrumented posterior lumbar interbody fusion. SUMMARY OF BACKGROUND DATA: Previous studies of sagittal alignment after posterior lumbar interbody fusion have focused on the impact of intraoperative patient, hip, and knee positioning, as well as instrumentation characteristics on sagittal posture. The influence of the cage shape on indexes of total and segmental sagittal alignment of the lumbar spine is yet unknown.
METHODS: Forty-two patients having undergone instrumented short-segment posterior lumbar interbody fusion were reviewed retrospectively. Twenty-two patients (12 women and 10 men, 38-78 years of age) had posterior lumbar interbody fusion with rectangular cages. The fused segments were: 4 at L3-L4, 16 at L4-L5, 11 at L5-S1. Thirteen patients had single- and nine patients double-level fusion. Twenty patients (8 women and 12 men, 34-81 years of age) had posterior lumbar interbody fusion with wedge-shaped cages. The fused segments were: 4 at L3-L4, 15 at L4-L5, 11 at L5-S1. Ten patients had single- and 10 patients double-level fusion. Cages were packed with cancellous bone from the posterior iliac crest and/or bone fragments harvested by laminectomy. All patients had additional pedicle screw fixation. Pre- and postoperative standing lateral radiographs were assessed for segmental and lumbar lordosis as well lumbar and sacral tilt. Data were analyzed with repeated measures analysis of variance. RESULTS The mean follow-up period was 18 months with a minimum follow-up period of 14 months. Mean segmental lordosis of the fused segments showed significant changes between the two implant groups (P < 0.05). Segmental lordosis decreased in the rectangular cage group from 10 degrees to 2 degrees at L3-L4, from 10 degrees to 5 degrees at L4-L5, and from 9 degrees before to 6 degrees after fusion surgery at L5-S1. In the wedge-shaped cage group, segmental lordosis increased from 4 degrees to 7 degrees at L3-L4, from 2 degrees to 8 degrees at L4-L5, and from 9 degrees to 17 degrees at L5-S1. Analysis of changes in lumbar lordosis and lumbar and sacral tilt did not show significant differences though opposite trends: lumbar lordosis decreased from 55 degrees to 48 degrees in the rectangular cage group and increased from 45 degrees to 53 degrees in the wedge-shaped cage group. Lumbar tilt measured 98 degrees before and 102 degrees after surgery in the rectangular cage group and 97 degrees before and 94 degrees after surgery. Sacral tilt measured 44 degrees before and 40 degrees after surgery in the rectangular cage group and measured 42 degrees before and 45 degrees after surgery in the wedge-shaped cage group.
CONCLUSIONS: The cage geometry has a significant impact on the alignment of the lumbar spine after instrumented posterior lumbar interbody fusion. With rectangular cages, lumbar lordosis and segmental lordosis of the segments fused decrease; sagittal balance is maintained by compensatory changes of the sacral tilt. Wedge-shaped cages significantly increase segmental lordosis, enhance lumbar lordosis, and therefore should be preferred for restoring sagittal alignment in instrumented posterior lumbar interbody fusion procedures.

Entities:  

Mesh:

Year:  2003        PMID: 12897494     DOI: 10.1097/01.BRS.0000083167.78853.D5

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  28 in total

1.  Quantitative analysis in outcome assessment of instrumented lumbosacral arthrodesis.

Authors:  Sabina Champain; Christian Mazel; Anca Mitulescu; Wafa Skalli
Journal:  Eur Spine J       Date:  2007-01-10       Impact factor: 3.134

Review 2.  [The PLIF and TLIF techniques. Indication, technique, advantages, and disadvantages].

Authors:  C Fleege; M Rickert; M Rauschmann
Journal:  Orthopade       Date:  2015-02       Impact factor: 1.087

Review 3.  Evidence showing the relationship between sagittal balance and clinical outcomes in surgical treatment of degenerative spinal diseases: a literature review.

Authors:  Jean-Charles Le Huec; Antonio Faundez; Dennis Dominguez; Pierre Hoffmeyer; Stéphane Aunoble
Journal:  Int Orthop       Date:  2014-09-06       Impact factor: 3.075

4.  Treatment of Symptomatic Lumbar Disc Degeneration with the VariLift-L Interbody Fusion System: Retrospective Review of 470 Cases.

Authors:  Warren F Neely; Frank Fichtel; Diana Cardenas Del Monaco; Jon E Block
Journal:  Int J Spine Surg       Date:  2016-05-03

5.  Do position and size matter? An analysis of cage and placement variables for optimum lordosis in PLIF reconstruction.

Authors:  Priyan R Landham; Angus S Don; Peter A Robertson
Journal:  Eur Spine J       Date:  2017-06-15       Impact factor: 3.134

6.  An 11-year minimum follow-up of the Charite III lumbar disc replacement for the treatment of symptomatic degenerative disc disease.

Authors:  Shi-bao Lu; Yong Hai; Chao Kong; Qing-yi Wang; Qingjun Su; Lei Zang; Nan Kang; Xiang-long Meng; Yu Wang
Journal:  Eur Spine J       Date:  2015-04-21       Impact factor: 3.134

7.  One and two level posterior lumbar interbody fusion (PLIF) using an expandable, stand-alone, interbody fusion device: a VariLift® case series.

Authors:  Rebecca Barrett-Tuck; Diana Del Monaco; Jon E Block
Journal:  J Spine Surg       Date:  2017-03

8.  Radiographic results of single level transforaminal lumbar interbody fusion in degenerative lumbar spine disease: focusing on changes of segmental lordosis in fusion segment.

Authors:  Sang-Bum Kim; Taek-Soo Jeon; Youn-Moo Heo; Woo-Suk Lee; Jin-Woong Yi; Tae-Kyun Kim; Cheol-Mog Hwang
Journal:  Clin Orthop Surg       Date:  2009-11-25

9.  Normative values for the spine shape parameters using 3D standing analysis from a database of 268 asymptomatic Caucasian and Japanese subjects.

Authors:  Jean Charles Le Huec; Kazuhiro Hasegawa
Journal:  Eur Spine J       Date:  2016-03-07       Impact factor: 3.134

10.  Comparison between Instrumented Mini-TLIF and Instrumented Circumferential Fusion in Adult Low-Grade Lytic Spondylolisthesis : Can Mini-TLIF with PPF Replace Circumferential Fusion?

Authors:  Jin-Sung Kim; Dong-Hyun Kim; Sang-Ho Lee
Journal:  J Korean Neurosurg Soc       Date:  2009-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.