Literature DB >> 12896834

A portable microelectrode array recording system incorporating cultured neuronal networks for neurotoxin detection.

Joseph J Pancrazio1, Samuel A Gray, Yura S Shubin, Nadezhda Kulagina, David S Cuttino, Kara M Shaffer, Kevin Eisemann, Anthony Curran, Bret Zim, Guenter W Gross, Thomas J O'Shaughnessy.   

Abstract

Cultured neuronal networks, which have the capacity to respond to a wide range of neuroactive compounds, have been suggested to be useful for both screening known analytes and unknown compounds for acute neuropharmacologic effects. Extracellular recording from cultured neuronal networks provides a means for extracting physiologically relevant activity, i.e. action potential firing, in a noninvasive manner conducive for long-term measurements. Previous work from our laboratory described prototype portable systems capable of high signal-to-noise extracellular recordings from cardiac myocytes. The present work describes a portable system tailored to monitoring neuronal extracellular potentials that readily incorporates standardized microelectrode arrays developed by and in use at the University of North Texas. This system utilizes low noise amplifier and filter boards, a two-stage thermal control system with integrated fluidics and a graphical user interface for data acquisition and control implemented on a personal computer. Wherever possible, off-the-shelf components have been utilized for system design and fabrication. During use with cultured neuronal networks, the system typically exhibits input referred noise levels of only 4-6 microVRMS, such that extracellular potentials exceeding 40 microV can be readily resolved. A flow rate of up to 1 ml/min was achieved while the cell recording chamber temperature was maintained within a range of 36-37 degrees C. To demonstrate the capability of this system to resolve small extracellular potentials, pharmacological experiments with cultured neuronal networks have been performed using ion channel blockers, tetrodotoxin and tityustoxin. The implications of the experiments for neurotoxin detection are discussed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12896834     DOI: 10.1016/s0956-5663(03)00092-7

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  18 in total

1.  Neuron-transistor coupling: interpretation of individual extracellular recorded signals.

Authors:  Sven Ingebrandt; Chi-Kong Yeung; Michael Krause; Andreas Offenhäusser
Journal:  Eur Biophys J       Date:  2005-03       Impact factor: 1.733

Review 2.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

3.  Short peptides enhance single cell adhesion and viability on microarrays.

Authors:  Mandana Veiseh; Omid Veiseh; Michael C Martin; Fareid Asphahani; Miqin Zhang
Journal:  Langmuir       Date:  2007-03-20       Impact factor: 3.882

4.  Automatic noise-level detection for extra-cellular micro-electrode recordings.

Authors:  Kevin Dolan; H C F Martens; P R Schuurman; L J Bour
Journal:  Med Biol Eng Comput       Date:  2009-05-26       Impact factor: 2.602

5.  The fabrication of low-impedance nanoporous gold multiple-electrode arrays for neural electrophysiology studies.

Authors:  Erkin Seker; Yevgeny Berdichevsky; Matthew R Begley; Michael L Reed; Kevin J Staley; Martin L Yarmush
Journal:  Nanotechnology       Date:  2010-03-05       Impact factor: 3.874

6.  Extracellular electrical signals in a neuron-surface junction: model of heterogeneous membrane conductivity.

Authors:  Pavel M Bulai; Pavel G Molchanov; Andrey A Denisov; Taras N Pitlik; Sergey N Cherenkevich
Journal:  Eur Biophys J       Date:  2012-02-12       Impact factor: 1.733

7.  Microfluidics Integration into Low-Noise Multi-Electrode Arrays.

Authors:  Mafalda Ribeiro; Pamela Ali; Benjamin Metcalfe; Despina Moschou; Paulo R F Rocha
Journal:  Micromachines (Basel)       Date:  2021-06-20       Impact factor: 2.891

Review 8.  Neural interfaces at the nanoscale.

Authors:  Joseph J Pancrazio
Journal:  Nanomedicine (Lond)       Date:  2008-12       Impact factor: 5.307

9.  Feasibility Assessment of Micro-Electrode Chip Assay as a Method of Detecting Neurotoxicity in vitro.

Authors:  Enrico Defranchi; Antonio Novellino; Maurice Whelan; Sandra Vogel; Tzutzuy Ramirez; Ben van Ravenzwaay; Robert Landsiedel
Journal:  Front Neuroeng       Date:  2011-04-28

10.  Development of micro-electrode array based tests for neurotoxicity: assessment of interlaboratory reproducibility with neuroactive chemicals.

Authors:  A Novellino; Bibiana Scelfo; T Palosaari; A Price; Tomasz Sobanski; T J Shafer; A F M Johnstone; G W Gross; A Gramowski; O Schroeder; K Jügelt; M Chiappalone; F Benfenati; S Martinoia; M T Tedesco; E Defranchi; P D'Angelo; M Whelan
Journal:  Front Neuroeng       Date:  2011-04-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.