Literature DB >> 12893311

Evaluation of redox mediators for amperometric biosensors: Ru-complex modified carbon-paste/enzyme electrodes.

Ekaterina V Ivanova1, Viktorya S Sergeeva, Joshua Oni, Christian Kurzawa, Alexander D Ryabov, Wolfgang Schuhmann.   

Abstract

The properties of reagentless amperometric biosensors are mainly governed by the interaction of the used redox enzyme and the redox mediators used to facilitate the electron-transfer reaction. Both the used redox mediators and the redox enzymes differ concerning their hydrophilicity and their properties within the matrix of a carbon-paste electrode. Since there is no general procedure which is applicable for any enzyme in combination with any redox mediator, optimisation is necessary for each possible combination. Three approaches for the development of biosensors were investigated using carbon-paste electrodes enriched with redox mediator as a base in all sensor architectures. A class of redox mediators with the common formula Ru(LL)(2)(X)(2) (where LL are 1,10-phenantroline or 2,2'-bipyridine type ligands, and X is an acido ligand) was investigated. In the first approach, enzymes were integrated into the carbon paste; in the second, the enzymes were adsorbed on the surface of the mediator-containing carbon-paste electrode and held in place by a Nafion film; and in the third approach, enzymes were entrapped in polymer films, which were electrochemically deposited onto the electrode's surface. The properties of the obtained biosensors strongly depend on the sensor architecture and the specific features of the used enzyme. Thus, our investigation using three different sensor architectures can provide valuable information about the possible interaction between a specific enzyme and a redox mediators with specific properties.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12893311     DOI: 10.1016/s1567-5394(03)00046-x

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  3 in total

1.  Coimmobilization of dehydrogenases and their cofactors in electrochemical biosensors.

Authors:  Maogen Zhang; Conor Mullens; Waldemar Gorski
Journal:  Anal Chem       Date:  2007-02-14       Impact factor: 6.986

2.  Assembling Amperometric Biosensors for Clinical Diagnostics.

Authors:  María Soledad Belluzo; María Elida Ribone; Claudia Marina Lagier
Journal:  Sensors (Basel)       Date:  2008-02-27       Impact factor: 3.576

3.  Development of a Glucose Sensor Based on Glucose Dehydrogenase Using Polydopamine-Functionalized Nanotubes.

Authors:  Won-Yong Jeon; Hyug-Han Kim; Young-Bong Choi
Journal:  Membranes (Basel)       Date:  2021-05-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.