Literature DB >> 1289098

On-line quantification of ventricular function during dobutamine stress echocardiography.

J E Pérez1, A D Waggoner, V G Dávila-Roman, H Cardona, J G Miller.   

Abstract

To develop an approach for on-line quantification of left ventricular size and function during pharmacological stress testing we employed echocardiographic automatic edge detection via integrated backscatter imaging during dobutamine infusion in 27 patients. Ventricular cavity areas, fractional area change and rate of cavity area change were obtained on-line with instantaneous graphic display of the data. When compared to baseline image data, patients with a normal response exhibited modest (15%) reduction in end-diastolic cavity areas at peak dobutamine level, but marked (33%) reduction in systolic areas yielding a 52% increase in fractional area change (n = 13; P < 0.001). The second group of patients (n = 14) had an abnormal response characterized by limited changes in measured parameters of ventricular function and reduced fractional area change (P < 0.05). On-line quantification during pharmacological stress echocardiography is a promising addition to the test for surveillance and objective instantaneous evaluation of global cardiac responses.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1289098     DOI: 10.1093/oxfordjournals.eurheartj.a060123

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  6 in total

1.  Comparison of methods of fractional area change for detection of regional left ventricular dysfunction.

Authors:  S Carstensen; U Hoest; L Kjoeller-Hansen; K Saunamäki; D Atar; H Kelbaek
Journal:  Int J Card Imaging       Date:  2000-08

2.  Between observer variation is not eliminated by standardised analysis of dobutamine-atropine stress echocardiography.

Authors:  Steen Carstensen; Henning Bundgaard; Lars Kjøller-Hansen; Dan Atar; Samir M Ali; Kari Saunamäki; Henning Kelbaek
Journal:  Int J Cardiovasc Imaging       Date:  2002-06       Impact factor: 2.357

3.  Stroke volume changes during dobutamine-atropine stress echocardiography: the influence of heart rate and ischaemia.

Authors:  D Poldermans; R Rambaldi; E Boersma; W Vletter; S Carlier; A Elhendy; J J Bax; A J Man in 't Veld; J R Roelandt
Journal:  Int J Card Imaging       Date:  1999-08

Review 4.  Detection of the fingerprint of the electrophysiological abnormalities that increase vulnerability to life-threatening ventricular arrhythmias.

Authors:  Michael E Cain; R Martin Arthur; Jason W Trobaugh
Journal:  J Interv Card Electrophysiol       Date:  2003-10       Impact factor: 1.900

5.  Left ventricular remodeling can be predicted with left ventricular volume response during dobutamine echocardiography after acute myocardial infarction.

Authors:  Se-Joong Rim; Jong-Won Ha; Moon-Hyoung Lee; Yangsoo Jang; Namsik Chung
Journal:  Clin Cardiol       Date:  2008-06       Impact factor: 2.882

6.  Mitral Annular Systolic Velocities Predict Left Ventricular Wall Motion Abnormality During Dobutamine Stress Echocardiography.

Authors:  Dawod Sharif; Amal Sharif-Rasslan; Camilia Shahla
Journal:  Cardiol Res       Date:  2011-01-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.