The output of four modern vaporizers in the presence of helium.

R G Loeb1.   

Abstract

It has been previously demonstrated that the output of calibrated vaporizers is influenced by the concentration of nitrous oxide in the carrier gas. This study was performed to determine whether helium in the carrier gas affects the output of modern calibrated vaporizers. A factorial design was used to determine the influence of carrier-gas helium concentration, carrier-gas flow rate and vaporizer dial setting on the output of four vaporizers: Ohio Calibrated Enflurane, Ohio Calibrated Isoflurane, Ohmeda Isotec 4, and Dräger Vapor 19.1 Isoflurane. Three vaporizers of each model were tested. Output was converted to % of baseline so that different dial settings could be compared. For a given dial setting, baseline was defined as the output at a carrier-gas flow rate of 3 L.min-1 and helium concentration of zero. The data were analyzed using multiple linear regression. There was an effect of helium concentration on vaporizer output in all models. None of these changes was clinically important, since vaporizer output did not vary by more than +/- 10%, except at high flows and at high helium concentrations with the Ohmeda Isotec 4. It is concluded that these vaporizers can be used safely with helium.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1288913     DOI: 10.1007/BF03008301

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  8 in total

1.  Helium-oxygen in treatment of upper airway obstruction.

Authors:  T S Lu; A Ohmura; K C Wong; M R Hodges
Journal:  Anesthesiology       Date:  1976-12       Impact factor: 7.892

2.  The effect of nitrous oxide on halothane output from Fluotec Mark 2 vaporizers.

Authors:  R K Stoelting
Journal:  Anesthesiology       Date:  1971-08       Impact factor: 7.892

3.  Evaluation of helium interference with mass spectrometry.

Authors:  M Siegel; N Gravenstein
Journal:  Anesth Analg       Date:  1988-09       Impact factor: 5.108

4.  Effects of carrier gas composition on the output of six anaesthetic vaporizers.

Authors:  E Palayiwa; M H Sanderson; C E Hahn
Journal:  Br J Anaesth       Date:  1983-10       Impact factor: 9.166

5.  Effect of nitrous oxide solubility on vaporizer aberrance.

Authors:  D B Gould; B A Lampert; T N MacKrell
Journal:  Anesth Analg       Date:  1982-11       Impact factor: 5.108

6.  Helium-oxygen mixtures in airway obstruction due to thyroid carcinoma.

Authors:  M Rudow; A B Hill; N W Thompson; J S Finch
Journal:  Can Anaesth Soc J       Date:  1986-07

7.  An evaluation of gas density dependence of anaesthetic vaporizers.

Authors:  L Prins; J Strupat; J Clement; R L Knill
Journal:  Can Anaesth Soc J       Date:  1980-03

8.  Helium retards endotracheal tube fires from carbon dioxide lasers.

Authors:  A G Pashayan; J S Gravenstein
Journal:  Anesthesiology       Date:  1985-03       Impact factor: 7.892

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.