Literature DB >> 12885179

Temporal patient state characterization using Iterative Order and Noise (ION) estimation: applications to anesthesia patient monitoring.

Gil Alterovitz1, David H Staelin, James H Philip.   

Abstract

OBJECTIVE: As more sensors are added to increasingly technology-dependent operating rooms (OR), physicians such as anesthesiologists must sift through an ever-increasing number of patient parameters every few seconds as part of their OR duties. To the extent these many parameters are correlated and redundant, manually monitoring all of them may not be an optimal physician strategy for assessing patient state or predicting future changes to guide their actions.
METHODS: The method is illustrated by application to seventy-six anesthetized patients for which thirty-two fundamental and derived variables were recorded at 20-second intervals. The Iterative Order and Noise estimation algorithm (ION) estimated the noise on each parameter. The performance of principal components analysis (PCA) was improved by normalizing the noise estimated by ION to unity. A linear regression of the resulting seven high signal-to-noise ratio principal components (PC's) predicted tachycardia 140 seconds in advance.
RESULTS: ION estimated the noise on each parameter with sufficient accuracy to increase the number of significant PC's from two to seven, all of which had identifiable physiological correlates. The resulting receiver operating characteristic (ROC) suggested that a 70 percent prediction rate with 5 percent false alarms could be achieved.
CONCLUSIONS: This paper illustrates the use of ION to improve significantly the performance of PCA in the efficient representation of patient state and in improving the performance of linear predictors of clinically significant parameters.

Entities:  

Mesh:

Year:  2002        PMID: 12885179     DOI: 10.1023/a:1024281817025

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  7 in total

1.  The physiological and physical factors governing the uptake of anesthetic gases by the body.

Authors:  S S KETY
Journal:  Anesthesiology       Date:  1950-09       Impact factor: 7.892

2.  The theory and applications of the exchange of inert gas at the lungs and tissues.

Authors:  S S KETY
Journal:  Pharmacol Rev       Date:  1951-03       Impact factor: 25.468

3.  Selecting the optimal anesthesia monitoring array.

Authors:  J H Philip; D B Raemer
Journal:  Med Instrum       Date:  1985 May-Jun

4.  Fast-track eligibility after ambulatory anesthesia: a comparison of desflurane, sevoflurane, and propofol.

Authors:  D Song; G P Joshi; P F White
Journal:  Anesth Analg       Date:  1998-02       Impact factor: 5.108

5.  Gas Man--an example of goal oriented computer-assisted teaching which results in learning.

Authors:  J H Philip
Journal:  Int J Clin Monit Comput       Date:  1986

6.  Neurocirculatory responses to sevoflurane in humans. A comparison to desflurane.

Authors:  T J Ebert; M Muzi; C W Lopatka
Journal:  Anesthesiology       Date:  1995-07       Impact factor: 7.892

7.  A lower solubility recommends the use of desflurane more than isoflurane, halothane, and enflurane under low-flow conditions.

Authors:  S Hargasser; R Hipp; B Breinbauer; L Mielke; E Entholzner; M Rust
Journal:  J Clin Anesth       Date:  1995-02       Impact factor: 9.452

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.