The value of radiochromic film dosimetry around air cavities: experimental results and Monte Carlo simulations.

L Paelinck1, N Reynaert, H Thierens, C De Wagter, W De Neve.   

Abstract

In this study we investigate radiochromic film dosimetry around air cavities with particular focus on the perturbation of the dose distribution by the film when the film is parallel to the beam axis. We considered a layered polystyrene phantom containing an air cavity as a model for the air-soft tissue geometry that may occur after surgical resection of a paranasal sinus tumour. A radiochromic film type MD-55 was positioned within the phantom so that it intersected the cavity. Two phantom set-ups were examined. In the first case, the air cavity is at the centre of the phantom, thus the film is lying along the central beam axis. In the second case, the cavity and film are located 2 cm offset from the phantom centre and the central beam axis. In order to examine the influence of the film on the dose distribution and to interpret the film-measured results, Monte Carlo simulations were performed. The film was modelled rigorously to incorporate the composition and structure of the film. Two field configurations, a 1 x 10 cm2 field and a 10 x 10 cm2 field, were examined. The dose behind the air cavity is reduced by 6 to 7% for both field configurations when a film that intersects the cavity contains the central beam axis. This is due to the attenuation exerted by the film when photons cross the cavity. Offsetting the beam to the cavity and the film by 2 cm removes the dose reduction behind the air cavity completely. Another result was that the rebuild-up behind the cavity for the 10 x 10 cm2 field, albeit less significant than for the 1 x 10 cm2 field, could only be measured by the film that was placed offset with respect to the central beam axis. Although radiochromic film is approximately soft-tissue equivalent and energy independent as compared to radiographic films, care should be taken in the case of inhomogeneous phantoms when the film intersects air cavities and contains the beam central axis. Errors in dose measurement can be expected distal to the air cavity due to attenuation in the film itself. This attenuation would not occur in the absence of the film. Both experiments and Monte Carlo computations support this conclusion.

Entities:  

Mesh:

Year:  2003        PMID: 12884923     DOI: 10.1088/0031-9155/48/13/303

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Endo-rectal balloon cavity dosimetry in a phantom: performance under IMRT and helical tomotherapy beams.

Authors:  Nicholas Hardcastle; Peter E Metcalfe; Anatoly B Rosenfeld; Wolfgang A Tomé
Journal:  Radiother Oncol       Date:  2009-03-30       Impact factor: 6.280

2.  A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours.

Authors:  Jan Seppala; Sami Suilamo; Jarmo Kulmala; Pekka Mali; Heikki Minn
Journal:  Radiat Oncol       Date:  2012-05-31       Impact factor: 3.481

3.  Investigating the Effect of Air Cavities of Sinuses on the Radiotherapy Dose Distribution Using Monte Carlo Method.

Authors:  F Seif; M R Bayatiani; S Hamidi; M Kargaran
Journal:  J Biomed Phys Eng       Date:  2019-02-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.