Blood flow in the tibialis anterior muscle by photoplethysmography during foot-transmitted vibration.

Qiuxia Zhang1, Klas Ericson, Jorma Styf.   

Abstract

Photoplethysmography (PPG) was used to detect changes in the anterior tibial muscle blood flow (MBF) during foot-transmitted vibration in six healthy subjects. A filter was developed for reducing the vibration-induced artefacts in the PPG signal. The vibration applied was random with constant acceleration power density in the range 5-2000 Hz with an acceleration of 16-46 m s(-2) (rms). The application of the filter technique showed a dramatic reduction in the vibration-induced artefacts and distortion of the PPG signal was negligible. The mean ratio and correlation coefficient of MBF originating from filtered and non-filtered PPG signals was [mean (SD)] 0.89 (0.04) and 0.99, respectively. This made it possible to detect a relative increase in MBF of 20% during an acute vibration exposure. The results suggest that the use of the filter enables MBF to be measured by PPG during vibration, thus extending the range of applications of the PPG technique to include ergonomic conditions.

Mesh:

Year:  2003        PMID: 12883903     DOI: 10.1007/s00421-003-0904-5

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  16 in total

1.  Effects of limb elevation and increased intramuscular pressure on human tibialis anterior muscle blood flow.

Authors:  Q Zhang; J Styf; L G Lindberg
Journal:  Eur J Appl Physiol       Date:  2001-10       Impact factor: 3.078

Review 2.  Skin photoplethysmography--a review.

Authors:  A A Kamal; J B Harness; G Irving; A J Mearns
Journal:  Comput Methods Programs Biomed       Date:  1989-04       Impact factor: 5.428

3.  Simultaneous assessment of muscle and skin blood fluxes with the laser-Doppler technique.

Authors:  U Hoffmann; I Uçkay; M Fischer; S Wen; U K Franzeck; A Bollinger
Journal:  Int J Microcirc Clin Exp       Date:  1995 Mar-Apr

4.  A non-invasive measure of changes in blood flow in the human anterior tibial muscle.

Authors:  Q Zhang; L G Lindberg; R Kadefors; J Styf
Journal:  Eur J Appl Physiol       Date:  2001-05       Impact factor: 3.078

5.  Diagnostic tests in Raynaud's phenomena in workers exposed to vibration: a comparative study.

Authors:  N Olsen
Journal:  Br J Ind Med       Date:  1988-06

6.  Single-fiber laser Doppler flowmetry. A method for deep tissue perfusion measurements.

Authors:  E G Salerud; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1987-05       Impact factor: 2.602

Review 7.  Hand-arm vibration syndrome.

Authors:  P L Pelmear; W Taylor
Journal:  J Fam Pract       Date:  1994-02       Impact factor: 0.493

8.  Acute effects of vibration on digital circulatory function in healthy men.

Authors:  M Bovenzi; M J Griffin; C M Ruffell
Journal:  Occup Environ Med       Date:  1995-12       Impact factor: 4.402

9.  Intramuscular laser-Doppler flowmetry in the supraspinatus muscle during isometric contractions.

Authors:  B R Jensen; G Sjøgaard; S Bornmyr; M Arborelius; K Jørgensen
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

10.  Regional blood flow during exercise in humans measured by near-infrared spectroscopy and indocyanine green.

Authors:  R Boushel; H Langberg; J Olesen; M Nowak; L Simonsen; J Bülow; M Kjaer
Journal:  J Appl Physiol (1985)       Date:  2000-11
View more
  1 in total

1.  Implementation of matrix rhythm therapy and conventional massage in young females and comparison of their acute effects on circulation.

Authors:  Ferruh Taspinar; Ummuhan Bas Aslan; Nuran Sabir; Ugur Cavlak
Journal:  J Altern Complement Med       Date:  2013-04-26       Impact factor: 2.579

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.