Literature DB >> 12883347

The effect of eye closure on the post-lens tear film thickness during silicone hydrogel contact lens wear.

Jason J Nichols1, P Ewen King-Smith.   

Abstract

PURPOSE: The purpose of this study was to investigate the effect of eye closure on the thickness on the post-lens tear film (POLTF) during silicone hydrogel contact lens wear.
METHODS: Ten subjects (mean age, 30.2 +/- 8.6 years; seven males) wore balafilcon A silicone hydrogel contact lenses in both eyes during the experimental procedure (power = -2.00 D, base curve = 8.6 mm). Previously described interference techniques, based on oscillations in reflectance spectra, were used to measure the post-lens tear film. Reflectance spectra (562-1030 nm) from the front of the eye wearing a contact lens were measured at normal incidence where the thickness of the POLTF was derived from the "frequency" of the oscillations. Six baseline measures of POLTF thickness were taken, followed by eye closure in the supine position for 30 minutes. Post-lens tear film thickness measures were taken after 5 and 15 minutes of eye closure. After 30 minutes of eye closure, 1 measure of POLTF was taken every minute for an additional 15 minutes.
RESULTS: The average baseline POLTF thickness was 2.00 +/- 0.30 microm (median, 2.00) for the 10 subjects. The average POLTF thickness decreased to 1.58 +/- 0.33 and 1.20 +/- 0.23 microm after 5 and 15 minutes of eye closure, respectively (repeated measures ANOVA, F = 42.18, P < 0.0001). Only 5 of 60 POLTF thickness estimates were obtained for the first 6 minutes following completion of 30 minutes of eye closure, indicating that the POLTF may be too thin (i.e., <1 microm) to measure using this method. However, there was a significant increase in POLTF thickness for 15 minutes after prolonged eye closure (mixed modeling regression, thickness = 0.85 + 0.07 x time after eye opening; P < 0.0001).
CONCLUSIONS: The POLTF thickness is rapidly reduced by eye closure during contact lens wear. After 30 minutes of eye closure, the POLTF thickness may be reduced to values less than 1 microm for the first several minutes after opening the eyes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12883347     DOI: 10.1097/00003226-200308000-00010

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  5 in total

1.  Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Authors:  Qi Chen; Jianhua Wang; Aizhu Tao; Meixiao Shen; Shuliang Jiao; Fan Lu
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-11-20       Impact factor: 4.799

Review 2.  Tear exchange and contact lenses: a review.

Authors:  Alex Muntz; Lakshman N Subbaraman; Luigina Sorbara; Lyndon Jones
Journal:  J Optom       Date:  2015-01-07

3.  Tear film measurement by optical reflectometry technique.

Authors:  Hui Lu; Michael R Wang; Jianhua Wang; Meixiao Shen
Journal:  J Biomed Opt       Date:  2014-02       Impact factor: 3.170

4.  The association between mucin balls and corneal infiltrative events during extended contact lens wear.

Authors:  Loretta Szczotka-Flynn; Beth Ann Benetz; Jonathan Lass; Matthew Albright; Beth Gillespie; Jana Kuo; Desmond Fonn; Ajay Sethi; Alfred Rimm
Journal:  Cornea       Date:  2011-05       Impact factor: 2.651

5.  The Effect of Diquafosol Ophthalmic Solution on Clinical Parameters and Visual Function in Soft Contact Lens-Related Dry Eye.

Authors:  Tomohiro Ogami; Hiroki Asano; Takahiro Hiraoka; Yoshiaki Yamada; Tetsuro Oshika
Journal:  Adv Ther       Date:  2021-09-29       Impact factor: 3.845

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.