Literature DB >> 12878989

Ultrasonic analysis of anthracycline-induced myocardial damage using cyclic variation of integrated backscatter.

Hideo Nagai1, Wataru Omi, Toyoshi Yuasa, Satoru Sakagami, Shigeo Takata, Kenichi Kobayashi.   

Abstract

To test the feasibility of integrated backscatter (IB) for detecting anthracycline cardiotoxicity, we performed conventional echocardiography and IB analysis. For interindividual comparison, 32 patients with non-Hodgkin's lymphoma and 14 control subjects were selected. Of the patients, 10 had been treated with doxorubicin doses of </=200 mg/m(2) (low dose), 15 with </=400 mg/m(2) (moderate dose), and 7 with >400 mg/m(2) (high dose). In intraindividual comparison, 8 patients were examined before doxorubicin therapy and at a dose of 100 mg/m(2) and 8 were examined before and at a 300-mg/m(2) dose. Cyclic variation of IB (CV-IB) was obtained at the left ventricular posterior wall, using a modified, commercially available system in M-mode format. In interindividual comparison, CV-IB in high- and moderate-dose groups was smaller. In intraindividual comparison, CV-IB decreased after treatment with 300 mg/m(2) of doxorubicin. CV-IB was affected in some patients treated with a moderate dose of doxorubicin. IB analysis may be helpful for detecting early anthracycline cardiotoxicity.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12878989     DOI: 10.1067/S0894-7317(03)00425-5

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Detection and monitoring of cardiotoxicity-what does modern cardiology offer?

Authors:  Ruxandra Jurcut; Hans Wildiers; Javier Ganame; Jan D'hooge; Robert Paridaens; Jens-Uwe Voigt
Journal:  Support Care Cancer       Date:  2008-01-16       Impact factor: 3.603

Review 2.  Cancer therapy and cardiotoxicity: the need of serial Doppler echocardiography.

Authors:  Maurizio Galderisi; Francesco Marra; Roberta Esposito; Vincenzo Schiano Lomoriello; Moira Pardo; Oreste de Divitiis
Journal:  Cardiovasc Ultrasound       Date:  2007-01-25       Impact factor: 2.062

3.  Serial assessment of myocardial properties using cyclic variation of integrated backscatter in an adriamycin-induced cardiomyopathy rat model.

Authors:  Jong-Won Ha; Seok-Min Kang; Wook-Bum Pyun; Joo-Yong Lee; Mi-Young Ahn; Woong-Chul Kang; Tae Joo Jeon; Namsik Chung; Jong-Doo Lee; Sang-Ho Cho
Journal:  Yonsei Med J       Date:  2005-02-28       Impact factor: 2.759

4.  Early detection of doxorubicin myocardial injury by ultrasonic tissue characterization in an experimental animal model.

Authors:  Minna Moreira Dias Romano; Antônio Pazin-Filho; João Lucas O'Connel; Marcus Vinícius Simões; André Schmidt; Érica C Campos; Marcos Rossi; Benedito Carlos Maciel
Journal:  Cardiovasc Ultrasound       Date:  2012-10-10       Impact factor: 2.062

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.