Literature DB >> 12878247

Visualisation of HIFU lesions using elastography of the human prostate in vivo: preliminary results.

Rémi Souchon1, Olivier Rouvière, Albert Gelet, Valérie Detti, Seshadri Srinivasan, Jonathan Ophir, Jean Yves Chapelon.   

Abstract

An imaging system was developed for prostate elastography in vivo using a transrectal ultrasound (US) probe to guide high-intensity focused US (HIFU) therapy of prostate cancer. Uniform compression was applied using a balloon, while a sector image was acquired. Strain was calculated from the gradient of the displacements obtained from the ultrasonic signal using the cross-correlation technique. Elastograms were acquired on a total of 31 patients undergoing HIFU therapy for localised prostate cancer. For two patients, only part of the prostate was treated and posttherapy magnetic resonance imaging (MRI) confirmed the size and position of the HIFU lesions seen in the elastograms as low strain areas, with a strain contrast ratio between 1.6 and 3.2. The whole prostate was treated for the next 29 patients. After treatment, the whole prostate appeared to be stiff in the elastograms and a 40% to 60% (mean 50%) decrease in average strain was observed when compared to strains measured before HIFU application. Tumours identified by biopsies and sonograms could occasionally be seen in the preoperative elastograms. Decorrelation effects occurred mainly because of low sonographic signal-to-noise ratio (SNR) and of out-of-plane motion induced by respiration.

Entities:  

Mesh:

Year:  2003        PMID: 12878247     DOI: 10.1016/s0301-5629(03)00065-6

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  40 in total

1.  Visualization of HIFU-induced lesion boundaries by axial-shear strain elastography: a feasibility study.

Authors:  Arun K Thittai; Belfor Galaz; Jonathan Ophir
Journal:  Ultrasound Med Biol       Date:  2011-01-26       Impact factor: 2.998

2.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

3.  Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding.

Authors:  Udomchai Techavipoo; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

4.  Prostate mechanical imaging: 3-D image composition and feature calculations.

Authors:  Vladimir Egorov; Suren Ayrapetyan; Armen P Sarvazyan
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

5.  Challenges and implementation of radiation-force imaging with an intracardiac ultrasound transducer.

Authors:  Stephen J Hsu; Brian J Fahey; Douglas M Dumont; Patrick D Wolf; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

6.  Ultrasound attenuation estimation using backscattered echoes from multiple sources.

Authors:  Timothy A Bigelow
Journal:  J Acoust Soc Am       Date:  2008-08       Impact factor: 1.840

7.  Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results.

Authors:  J Chenot; D Melodelima; W A N'djin; Rémi Souchon; M Rivoire; J Y Chapelon
Journal:  Phys Med Biol       Date:  2010-05-17       Impact factor: 3.609

8.  Real-time sonoelastography of hepatic thermal lesions in a swine model.

Authors:  Man Zhang; Benjamin Castaneda; Jared Christensen; Wael E Saad; Kevin Bylund; Kenneth Hoyt; John G Strang; Deborah J Rubens; Kevin J Parker
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

9.  Multi-parametric monitoring and assessment of high-intensity focused ultrasound (HIFU) boiling by harmonic motion imaging for focused ultrasound (HMIFU): an ex vivo feasibility study.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

Review 10.  Tissue elasticity properties as biomarkers for prostate cancer.

Authors:  Kenneth Hoyt; Benjamin Castaneda; Man Zhang; Priya Nigwekar; P Anthony di Sant'agnese; Jean V Joseph; John Strang; Deborah J Rubens; Kevin J Parker
Journal:  Cancer Biomark       Date:  2008       Impact factor: 4.388

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.