Literature DB >> 12878238

Volumetric assessment of normal fetal lungs using three-dimensional ultrasound.

Chiung-Hsin Chang1, Chen-Hsiang Yu, Fong-Ming Chang, Huei-Chen Ko, Hsi-Yao Chen.   

Abstract

We attempted to construct normal reference centiles of fetal lung volume (LV) for clinical application by using three-dimensional (3-D) ultrasound (US) during normal gestation. A prospective study was performed on 195 healthy fetuses with gestational age (GA) ranging from 20 to 40 weeks for the assessment of fetal LV using a 3-D US volume scanner with a mixture of cross-sectional and serial measurements. Polynomial regression analysis was calculated to find the best-fit model between GA, right lung volume (RLV), left lung volume (LLV) and total lung volume (TLV). In addition, common fetal growth parameters, such as biparietal diameter (BPD), occipitofrontal diameter (OFD), head circumference (HCi), abdominal circumference (ACi), femur length (FL) and estimated fetal weight (EFW) were also measured to demonstrate the correlations between RLV, LLV, TLV and these parameters. Our results showed that RLV, LLV and TLV were highly correlated with GA. Using GA as the independent variable and RLV, LLV and TLV as the dependent variable, the best-fit regression equations were: RLV (mL) = 0.067 GA(2) - 1.2464 GA + 2.7825 (r = 0.95, n = 173, p < 0.0001), LLV (mL) = 0.0573 GA(2) - 1.599 GA + 12.454 (r = 0.95, n = 159, p < 0.0001) and TLV (mL) = 0.1263 GA(2) - 2.982 GA + 17.448 (r = 0.96, n = 152, p < 0.0001). For clinical use, a chart of normal growth centiles of fetal LV in utero was then calculated based on this equation. Furthermore, RLV, LLV and TLV were also highly correlated with the common fetal growth parameters during normal gestation (all p < 0.0001). In conclusion, the 3-D US nomograms of the fetal lung volume established in this study can be utilized as useful references in prenatal detection of fetal pulmonary pathologic status and relevant abnormalities.

Entities:  

Mesh:

Year:  2003        PMID: 12878238     DOI: 10.1016/s0301-5629(03)00902-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering.

Authors:  Jin Yamamura; Michael Frisch; Hannes Ecker; Joachim Graessner; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2010-07-30       Impact factor: 5.315

Review 2.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

3.  High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus.

Authors:  Jin Yamamura; Bernhard Schnackenburg; Hendrik Kooijmann; Michael Frisch; Kurt Hecher; Gerhard Adam; Ulrike Wedegärtner
Journal:  Eur Radiol       Date:  2009-05-09       Impact factor: 5.315

4.  Volumetric growth of the lungs in human fetuses: an anatomical, hydrostatic and statistical study.

Authors:  Michał Szpinda; Waldemar Siedlaczek; Anna Szpinda; Alina Woźniak; Celestyna Mila-Kierzenkowska; Marcin Wiśniewski
Journal:  Surg Radiol Anat       Date:  2014-02-18       Impact factor: 1.246

5.  Quantitative Anatomy of the Growing Lungs in the Human Fetus.

Authors:  Michał Szpinda; Waldemar Siedlaczek; Anna Szpinda; Alina Woźniak; Celestyna Mila-Kierzenkowska; Mateusz Badura
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.