Literature DB >> 12878027

Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments.

G Abbas1, G J P Fleming, E Harrington, A C C Shortall, F J T Burke.   

Abstract

INTRODUCTION: The aim of this study was to investigate the effect of two novel curing systems (a plasma arc light, and a 'turbo-boosted' conventional curing light) on cuspal movement and gingival microleakage of 'packable' resin-based composite (RBC) restorations placed in extracted maxillary premolar teeth.
MATERIALS AND METHODS: Forty sound extracted upper premolar teeth were subjected to standardised preparation of a large mesio-occlusal-distal cavity before restoration with a RBC. Four curing regimens were used. Either the RBC was placed in bulk and light-cured in one increment using (a). the plasma arc light; (b). the 'turbo-boosted' curing light, or the RBC was placed in eight increments using (c). the plasma arc light; (d). the 'turbo-boosted' curing light. A deflection measuring gauge allowed a measurement of cuspal deflection at each stage of polymerisation. Restored teeth were thermocycled before immersion in a 0.2% basic fuchsin dye for 24 h. After sagittal sectioning of the restored teeth in a mesio-distal plane, the sectioned restorations were examined to assess cervical microleakage.
RESULTS: Cuspal deflection measurements were significantly increased when the 'turbo-boosted' halogen curing light was compared with the plasma arc light. Total mean cuspal deflection measurements obtained with incremental cure were significantly increased compared with bulk cure for both light sources. Gingival microleakage for bulk restored teeth was significantly increased compared with teeth restored incrementally. Incremental restoration with the plasma arc light had significantly increased gingival microleakage compared with the 'turbo-boosted' halogen curing light.
CONCLUSIONS: The packable composite tested could not be cured adequately to a depth of 5 mm with the plasma arc light within the specified irradiation time. Under the test conditions of the current investigation, bulk curing only appeared to be practical with the high intensity halogen light (40 s activation). Incremental build-up and polymerisation optimised marginal seal for the high intensity halogen light but led to greater cuspal deflection.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12878027     DOI: 10.1016/s0300-5712(02)00121-5

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  29 in total

Review 1.  Polymerization shrinkage assessment of dental resin composites: a literature review.

Authors:  Dalia Kaisarly; Moataz El Gezawi
Journal:  Odontology       Date:  2016-08-19       Impact factor: 2.634

2.  Influence of increment thickness on dentin bond strength and light transmission of composite base materials.

Authors:  Tarek A Omran; Sufyan Garoushi; Aous A Abdulmajeed; Lippo V Lassila; Pekka K Vallittu
Journal:  Clin Oral Investig       Date:  2016-09-10       Impact factor: 3.573

3.  Microleakage of "Bulk-Fill" Composite Resin for Class II Restorations Pretreated With CO2 Laser in Deciduous Molars: An In Vitro Study.

Authors:  Larissa Costa Santos; Ravana Angelini Sfalcin; Eugenio José Garcia; Fátima Antônia Aparecida Zanin; Aldo Brugnera Junior; Daniela Fátima Teixeira Silva; Anna Carolina Ratto Tempestini Horliana; Kristianne Porta Santos Fernandes; Raquel Agnelli Mesquita-Ferrari; Sandra Kalil Bussadori
Journal:  J Lasers Med Sci       Date:  2019-10-01

4.  Effect of composite type and placement technique on cuspal strain.

Authors:  Vilhelm G Ólafsson; André V Ritter; Edward J Swift; Lee W Boushell; Ching-Chang Ko; Gabrielle R Jackson; Sumitha N Ahmed; Terence E Donovan
Journal:  J Esthet Restor Dent       Date:  2017-10-16       Impact factor: 2.843

5.  Marginal quality of a full-body bulk-fill composite placed with an universal adhesive system in etch-and-rinse and self-etch mode: An in vitrostudy.

Authors:  Antonio Signore; Luca Solimei; Marianna-Georgievna Arakelyan; Alina-Vladimirova Arzukanyan; Nicola De Angelis; Andrea Amaroli
Journal:  J Clin Exp Dent       Date:  2021-08-01

6.  The effect of functionalized titanium dioxide nanotube reinforcement on the water sorption and water solubility properties of flowable bulk-fill composite resins.

Authors:  Mustafa Kutay Karaca; Ozge Kam Hepdeniz; Banu Esencan Turkaslan; Osman Gurdal
Journal:  Odontology       Date:  2021-10-13       Impact factor: 2.634

7.  Shrinkage Stresses Generated during Resin-Composite Applications: A Review.

Authors:  Luis Felipe J Schneider; Larissa Maria Cavalcante; Nick Silikas
Journal:  J Dent Biomech       Date:  2009-09-30

8.  Clinical performance of class I cavities restored with bulk fill composite at a 1-year follow-up using the FDI criteria: a randomized clinical trial.

Authors:  Chinni Suneelkumar; Puttaganti Harshala; Koppolu Madhusudhana; Anumula Lavanya; Anirudhan Subha; Sannapureddy Swapna
Journal:  Restor Dent Endod       Date:  2021-04-16

9.  Microtensile Bond Strength of Fiber-Reinforced and Particulate Filler Composite to Coronal and Pulp Chamber Floor Dentin.

Authors:  Anja Baraba; Samir Cimic; Matteo Basso; Andrei C Ionescu; Eugenio Brambilla; Ivana Miletić
Journal:  Materials (Basel)       Date:  2021-05-05       Impact factor: 3.623

10.  Posterior composite restoration update: focus on factors influencing form and function.

Authors:  Brenda S Bohaty; Qiang Ye; Anil Misra; Fabio Sene; Paulette Spencer
Journal:  Clin Cosmet Investig Dent       Date:  2013-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.