Literature DB >> 12874519

Time-related changes of radiofrequency ablation lesion in the normal rabbit liver: findings of magnetic resonance imaging and histopathology.

Masashi Tsuda1, Hiroya Rikimaru, Kazuhiro Majima, Takayuki Yamada, Haruo Saito, Tadashi Ishibashi, Shoki Takahashi, Hideo Miyachi, Mareyuki Endoh, Shogo Yamada.   

Abstract

RATIONALE AND
OBJECTIVES: To study time-related magnetic resonance imaging (MRI) and histopathological findings after radiofrequency ablation (RFA) in the normal liver.
METHODS: Under ultrasound guidance, RFA was performed in 22 rabbits with a 15-gauge expandable probe inserted into the liver. The RF power was applied at 10 W initially with a 5-W increment every minute until RF power "roll-off" occurred. The rabbits subjected to postmortem MRI at 3 days (n = 6), 2 weeks (n = 6), 4 weeks (n = 6), and 12 weeks (n = 4) after RFA. Spin-echo (SE) T(1)-weighted image (WI) (TR/TE=500/12) and fast SE T2-WI (TR/TE= 3500/99) were obtained. The liver specimens were excised and processed for conventional histologic study. The MRI and pathologic findings were compared qualitatively and quantitatively.
RESULTS: The lesion diameters measured with MRI and liver specimen were well correlated (P < 0.05). The coagulated regions presented 2 of 4 laminar patterns on T1/T2-WI 3 days after RFA, and 2 of 3 laminar patterns on T1/T2-WI 2 to 4 weeks after RFA. 12 weeks after RFA, the signal intensity in coagulated regions increased on T1-WI with a 2-laminar pattern still visible on T2-WI, the same as that of 2 to 4 weeks. The observed pathologic changes (enlarged sinusoids, marginal fibrous tissue and hepatocyte degeneration) could be responsible for the MRI laminar patterns and signal intensity changes.
CONCLUSION: The time-related pathologic changes of RFA lesions in rabbit livers can be reflected as laminar patterns on MR images. Understanding of the zone structure of the lesions is useful for the evaluation of follow-up MRI.

Entities:  

Mesh:

Year:  2003        PMID: 12874519     DOI: 10.1097/01.rli.0000073447.32361.b3

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

1.  Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours.

Authors:  Hansjörg Rempp; Rüdiger Hoffmann; Jörg Roland; Alexandra Buck; Antje Kickhefel; Claus D Claussen; Philippe L Pereira; Fritz Schick; Stephan Clasen
Journal:  Eur Radiol       Date:  2011-11-22       Impact factor: 5.315

2.  A tumor map generated from three-dimensional visualization of image fusion for the assessment of microwave ablation of hepatocellular carcinoma: a preliminary study.

Authors:  Chao An; Xin Li; Ping Liang; Jie Yu; Zhigang Cheng; Zhiyu Han; Fangyi Liu; Linan Dong
Journal:  Cancer Manag Res       Date:  2019-02-15       Impact factor: 3.989

3.  Influence of interapplicator distance on multibipolar radiofrequency ablation during physiological and interrupted liver perfusion in an in vivo porcine model.

Authors:  F G M Poch; C A Neizert; B Geyer; O Gemeinhardt; L Bruder; S M Niehues; J L Vahldiek; K K Bressem; M E Kreis; K S Lehmann
Journal:  Sci Rep       Date:  2020-10-01       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.