Literature DB >> 12873290

Evaluation of a new non-mydriatic digital camera for detection of diabetic retinopathy.

P Massin1, A Erginay, A Ben Mehidi, E Vicaut, G Quentel, Z Victor, M Marre, P J Guillausseau, A Gaudric.   

Abstract

AIMS: To compare the results of fundus photography using a new non-mydriatic digital camera with the results of reference standard of Early Treatment Diabetic Retinopathy Study (ETDRS) retinal photographs, for the detection of diabetic retinopathy (DR).
METHODS: Fundus colour photographs were taken with a Topcon non-mydriatic camera of 147 eyes of 74 diabetic patients, without pupillary dilation (five overlapping fields of 45 degrees; posterior pole, nasal, temporal, superior and inferior). Three retinal specialists classified the photographs in a masked fashion, as showing no DR or mild non-proliferative DR (NPDR) not requiring referral, moderate or more severe NPDR and/or macular oedema, or as non-gradable image requiring referral. ETDRS 35-mm colour slides served as reference images for DR detection.
RESULTS: For moderately severe to severe DR, the sensitivities of detection reported by the three observers were 92, 100 and 92%, respectively, and the specificities, 87, 85, and 88%. For four levels of DR severity (none or mild NPDR, moderate NPDR, severe NPDR and proliferative DR), the percentages of exact agreement between the three observers on the retinopathy grades assigned to the non-mydriatic photographs and to the ETDRS reference slides were 94.6, 93 and 87.6%, respectively (kappa 0.60-0.80). Sixteen eyes of nine patients (11%) were judged ungradable by at least one observer. In a second series of 110 patients, evaluated in the setting of a screening procedure, fewer photographs were ungradable (< 6%).
CONCLUSION: These results suggest that fundus photographs taken by the Topcon TRC-NW6S non-mydriatic camera, without pupillary dilation, are suitable for DR screening.

Entities:  

Mesh:

Year:  2003        PMID: 12873290     DOI: 10.1046/j.1464-5491.2003.01002.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  24 in total

1.  Link between retinopathy and nephropathy caused by complications of diabetes mellitus type 2.

Authors:  Pavel Kotlarsky; Arkady Bolotin; Karina Dorfman; Boris Knyazer; Tova Lifshitz; Jaime Levy
Journal:  Int Ophthalmol       Date:  2014-11-13       Impact factor: 2.031

2.  Diabetes eye screening in urban settings serving minority populations: detection of diabetic retinopathy and other ocular findings using telemedicine.

Authors:  Cynthia Owsley; Gerald McGwin; David J Lee; Byron L Lam; David S Friedman; Emily W Gower; Julia A Haller; Lisa A Hark; Jinan Saaddine
Journal:  JAMA Ophthalmol       Date:  2015-02       Impact factor: 7.389

3.  The impact of the Health Technology Board for Scotland's grading model on referrals to ophthalmology services.

Authors:  S Philip; L M Cowie; J A Olson
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

4.  [Fundus screening by medical technicians].

Authors:  F Schütt; T Bruckner; K Schäfer; D Lehnhoff; G Rudofsky; C Kasperk; P Nawroth; G U Auffarth
Journal:  Ophthalmologe       Date:  2013-02       Impact factor: 1.059

5.  Screening for Diabetic Retinopathy Using a Portable, Noncontact, Nonmydriatic Handheld Retinal Camera.

Authors:  Wenlan Zhang; Peter Nicholas; Stefanie Gail Schuman; Michael John Allingham; Ambar Faridi; Tushar Suthar; Scott William Cousins; Sasapin Grace Prakalapakorn
Journal:  J Diabetes Sci Technol       Date:  2016-07-11

6.  Feasibility study on computer-aided screening for diabetic retinopathy.

Authors:  Apichart Singalavanija; Jirayuth Supokavej; Parapan Bamroongsuk; Chanjira Sinthanayothin; Suthee Phoojaruenchanachai; Viravud Kongbunkiat
Journal:  Jpn J Ophthalmol       Date:  2006 Jul-Aug       Impact factor: 2.447

7.  Quality of nonmydriatic digital fundus photography obtained by nurse practitioners in the emergency department: the FOTO-ED study.

Authors:  Cédric Lamirel; Beau B Bruce; David W Wright; Kevin P Delaney; Nancy J Newman; Valérie Biousse
Journal:  Ophthalmology       Date:  2012-01-03       Impact factor: 12.079

8.  The accuracy of digital-video retinal imaging to screen for diabetic retinopathy: an analysis of two digital-video retinal imaging systems using standard stereoscopic seven-field photography and dilated clinical examination as reference standards.

Authors:  Mary Gilbert Lawrence
Journal:  Trans Am Ophthalmol Soc       Date:  2004

9.  Accuracy of digital images for assessing diabetic retinopathy.

Authors:  Hyungjin Myra Kim; Julie C Lowery; Ronald Kurtz
Journal:  J Diabetes Sci Technol       Date:  2007-07

10.  Evaluation of diabetic retinopathy screening using a non-mydriatic retinal digital camera in primary care settings in south Israel.

Authors:  Yossi Mizrachi; Boris Knyazer; Sara Guigui; Shirley Rosen; Tova Lifshitz; Nadav Belfair; Itamar Klemperer; Marina Schneck; Jaime Levy
Journal:  Int Ophthalmol       Date:  2013-12-01       Impact factor: 2.031