Literature DB >> 12872102

Prospective controlled assessment of variable stiffness enteroscopy.

Gavin C Harewood1, Christopher J Gostout, Michael A Farrell, Mary A Knipschield.   

Abstract

BACKGROUND: Push enteroscopy is a well-established technique for evaluation of the small intestine. However, looping of the enteroscope within the stomach limits depth of insertion. Stiffening overtubes that minimize gastric looping are tolerated marginally by patients and disliked by endoscopists. A variable stiffness instrument has the potential to eliminate the need for an overtube while still minimizing gastric looping. The performance of a prototype variable stiffness enteroscope was compared prospectively with that of a conventional push enteroscope with and without use of an overtube.
METHODS: Consecutive patients undergoing enteroscopy were randomized to have the procedure with a variable stiffness instrument, a conventional instrument with overtube, or a conventional instrument without overtube. Depth of insertion distal to the ligament of Treitz was determined by plain abdominal radiography. OBSERVATIONS: In total, 67 patients were randomized to variable stiffness enteroscopy (25 patients), enteroscopy with overtube (23 patients), and enteroscopy without overtube (19 patients). Median depth of insertion distal to the ligament of Treitz, respectively, for each group, was 89 cm, 68 cm and 41 cm (p = 0.03). In multivariate analysis, variable stiffness instrument use was predictive of intubation to 65 cm distal to the ligament of Treitz (odds ratio 5.53: 95% CI [1.25, 31.25] vs. no overtube, and odds ratio 2.50: 95% CI [0.63, 11.1] vs. overtube). Procedure duration and overall patient tolerance did not differ significantly among the 3 groups, although more patients in the overtube group required additional sedation than patients in the variable stiffness group (p = 0.03). Both endoscopists' (r = 0.34) and nurses' (r = 0.36) estimates of patient discomfort during the procedure correlated poorly with patient tolerance.
CONCLUSIONS: A variable stiffness push enteroscope enhances insertion depth compared with the conventional instrument with or without overtube. Further studies are required to determine whether this improved performance increases diagnostic yield.

Entities:  

Mesh:

Year:  2003        PMID: 12872102     DOI: 10.1067/mge.2003.365

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  6 in total

Review 1.  Role of video endoscopy in managing small bowel disease.

Authors:  P Swain; A Fritscher-Ravens
Journal:  Gut       Date:  2004-12       Impact factor: 23.059

2.  Role of wireless capsule endoscopy in inflammatory bowel disease.

Authors:  Eduardo Redondo-Cerezo
Journal:  World J Gastrointest Endosc       Date:  2010-05-16

Review 3.  Exploring the Small Bowel: Update on Deep Enteroscopy.

Authors:  Brian P Riff; Christopher J DiMaio
Journal:  Curr Gastroenterol Rep       Date:  2016-06

4.  ACG Clinical Guideline: Diagnosis and Management of Small Bowel Bleeding.

Authors:  Lauren B Gerson; Jeff L Fidler; David R Cave; Jonathan A Leighton
Journal:  Am J Gastroenterol       Date:  2015-08-25       Impact factor: 10.864

Review 5.  Enteroscopy in small bowel Crohn's disease: A review.

Authors:  Benjamin Tharian; Grant Caddy; Tony Ck Tham
Journal:  World J Gastrointest Endosc       Date:  2013-10-16

Review 6.  Small bowel imaging in Crohn's disease patients.

Authors:  James Gauci; Lara Sammut; Martina Sciberras; Naomi Piscopo; Kristian Micallef; Kelvin Cortis; Pierre Ellul
Journal:  Ann Gastroenterol       Date:  2018-05-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.