Literature DB >> 12871459

Blood coagulation in anhepatic pigs: effects of treatment with the AMC-bioartificial liver.

M N Sosef1, M-P Van De Kerkhove, S L Abrahamse, M M Levi, R A F M Chamuleau, T M Van Gulik.   

Abstract

The function of a newly devised bioartificial liver (AMC-BAL) based on viable, freshly isolated porcine hepatocytes has been evaluated in anhepatic pigs. The aim of this study was to assess the contribution of BAL treatment on blood coagulation parameters. Pigs were anesthetized and a total hepatectomy was performed (n = 15). The infrahepatic caval vein and the portal vein were connected to the subdiaphragmatic caval vein using a three-way prosthesis. Animals received standard intensive care (control, n= 5), treatment with an empty BAL (device control, n= 5) or with a cell-loaded BAL (BAL-treatment, n= 5) for a period of 24 h starting 24 h after hepatectomy. Coagulation parameters studied concerned prothrombin time (PT), platelet count, the procoagulant system (factors (F)II, FV, FVII, FVIII and fibrinogen), anticoagulant system (AT III), fibrinolytic system (t-PA, PAI-1) as well as markers of coagulation factor activation (TAT complexes, prothrombin fragment F1 + 2). FII, FV, FVII, AT III and fibrinogen rapidly decreased after total hepatectomy in pigs in accordance with the anhepatic state of the animals. FVIII levels were not influenced by the hepatectomy. A mild drop in platelet count was seen in all groups. Treatment of anhepatic pigs with the cell-loaded BAL did not restore PT or clotting factor levels. TAT and F1 + 2 complexes, however, were significantly increased in this group. Levels of t-PA and PAI-1 were not influenced by cell-loaded BAL treatment. Treatment of anhepatic pigs with the AMC-BAL based on freshly isolated porcine hepatocytes does not result in an improved coagulation state due to extensive consumption of clotting factors. However, increased levels of TAT complexes and prothrombin fragments F1 + 2 during treatment of anhepatic pigs indicate synthesis and direct activation of coagulation factors, leading to thrombin generation. This demonstrates that this bioartificial liver is capable of synthesizing coagulation factors.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12871459     DOI: 10.1046/j.1538-7836.2003.00082.x

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  3 in total

1.  Hepatic function after genetically engineered pig liver transplantation in baboons.

Authors:  Burcin Ekser; Gabriel J Echeverri; Andrea Cortese Hassett; Mark H Yazer; Cassandra Long; Michael Meyer; Mohamed Ezzelarab; Chih Che Lin; Hidetaka Hara; Dirk J van der Windt; Eefje M Dons; Carol Phelps; David Ayares; David K C Cooper; Bruno Gridelli
Journal:  Transplantation       Date:  2010-09-15       Impact factor: 4.939

Review 2.  Clinical application of bioartificial liver support systems.

Authors:  Maarten Paul van de Kerkhove; Ruurdtje Hoekstra; Robert A F M Chamuleau; Thomas M van Gulik
Journal:  Ann Surg       Date:  2004-08       Impact factor: 12.969

3.  alpha-Thrombin inhibits DNA synthesis in rat hepatocytes but not in hepatoma cells by receptor activation and proteolysis.

Authors:  Siddhartha Kar; Meifang Wang; Brian I Carr
Journal:  Mol Cell Biochem       Date:  2007-05-22       Impact factor: 3.396

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.