The effect of haemodilution on blood-biomaterial contact-mediated CD11b expression on neutrophils: ex vivo studies.

Terence Gourlay1, Ioannis Samartzis, Kenneth M Taylor.   

Abstract

Modern cardiopulmonary bypass (CPB) systems are getting smaller, both in terms of the exposed surface area of biomaterials and the priming volume. In a series of studies utilizing a rat recirculation model, we demonstrated that the magnitude of the inflammatory response seen under these conditions is proportional to the surface area of exposed material, a finding that supports the use of miniature systems in terms of moderating the inflammatory response. However, the second impact of miniature perfusion systems, the reduced priming volume with concomitant reduction in haemodilution, was not investigated with reference to inflammation. The present study was designed to determine whether this change in CPB haematocrit profile has any effect on the inflammatory response. In common with previous studies by this group, we employed the expression of the integrin CD11b on neutrophils as a marker of neutrophil activation, and hence the inflammatory response, in a rat recirculation biomaterial testing model, containing di-(2-ethyl-hexyl)-phthalate plasticized polyvinyl chloride of the type commonly employed in CPB circuits. The results demonstrated that neutrophil activation is influenced by haemodilution. We studied five groups of animals, each with different mean induced haematocrit: Group 1 (41.3 +/- 1.27%); Group 2 (30.93 +/- 2.85%); Group 3 (24.83 +/- 1.36%); Group 4 (20.60 +/- 3.47%); Group 5 (20.48 +/- 1.31%). Groups 1 and 5 animals were controls, neither of which underwent the period of recirculation. Rather, these controls were employed to isolate the noncontact effect of haemodilution on CD11b expression. We found that there were differences in per cent change in CD11b expression from start to end of the recirculation period between Group 1 (109.54 +/- 49.53%), Group 2 (189.1 +/- 18.68%), Group 3 (224.28 +/- 43.97), Group 4 (368.97 +/- 24.28%) and Group 5 (127 +/- 57.8%). There were intergroup statistically significant differences (p < 0.05). These results confirm that there is a relationship between haematocrit level and biomaterial contact-mediated activation of neutrophils. Furthermore, these studies confirm that haemodilution alone has no effect on neutrophil activation. One possible explanation for this outcome is that with higher levels of haemodilution, neutrophils have a greater opportunity to contact surface 'receptor' sites on the biomaterial, resulting in more neutrophil activation. Whatever the mechanism, these data tend to support the modern trend towards lower circuit surface area and higher haematocrit.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12868786     DOI: 10.1191/0267659103pf648oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  3 in total

1.  Rewarming From Hypothermic Cardiac Arrest Applying Extracorporeal Life Support: A Systematic Review and Meta-Analysis.

Authors:  Lars J Bjertnæs; Kristian Hindberg; Torvind O Næsheim; Evgeny V Suborov; Eirik Reierth; Mikhail Y Kirov; Konstantin M Lebedinskii; Torkjel Tveita
Journal:  Front Med (Lausanne)       Date:  2021-05-13

Review 2.  The inflammatory response to extracorporeal membrane oxygenation (ECMO): a review of the pathophysiology.

Authors:  Jonathan E Millar; Jonathon P Fanning; Charles I McDonald; Daniel F McAuley; John F Fraser
Journal:  Crit Care       Date:  2016-11-28       Impact factor: 9.097

3.  Left ventricular assist device implants in patients on extracorporeal membrane oxygenation: do we need cardiopulmonary bypass?

Authors:  Federico Pappalardo; Evgenij Potapov; Antonio Loforte; Michiel Morshuis; David Schibilsky; Daniel Zimpfer; Julia Riebandt; Christian Etz; Matteo Attisani; Mauro Rinaldi; Assad Haneya; Faiz Ramjankhan; Dirk Donker; Ulrich P Jorde; Daniel Lewin; Radi Wieloch; Rafael Ayala; Jochen Cremer; Letizia Bertoldi; Michael Borger; Artur Lichtenberg; Jan Gummert; Diyar Saeed
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-03-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.