Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation.

Homan Dehnad1, Aart J Nederveen, Uulke A van der Heide, R Jeroen A van Moorselaar, Pieter Hofman, Jan J W Lagendijk.   

Abstract

BACKGROUND AND
PURPOSE: The aim of this study was to assess the feasibility of using gold seed implants in the prostate for position verification, using an a-Si flat panel imager as a detector during megavoltage irradiation of prostate carcinoma. This is a study to guarantee positioning accuracy in intensity-modulated radiotherapy. METHODS AND MATERIALS: Ten patients with localized prostate carcinoma (T2-3) received between one and three fiducial gold markers in the prostate. All patients were treated with 3-D conformal radiotherapy with an anterior-posterior (AP) and two lateral wedge fields. The acute gastrointestinal (GI) and genitourinary (GU) toxicities were scored using common toxicity criteria scales (CTC). Using three consecutive CT scans and portal images obtained during the treatment we have studied the occurrence of any change in prostate shape (deformation), seed migration and the magnitude of translations and rotations of the prostate.
RESULTS: We observed no acute major complications for prostate irradiation regarding the seed implantation. The maximum acute GU toxicity grade 2 (dysuria and frequency) was observed in seven patients during the treatment. The maximum grade 2 (diarrhoea) was scored in two patients regarding the acute GI toxicities. No significant prostate deformation could be detected in the consecutive CT scans. It appeared that the distances between the markers only slightly changed during treatment (S.D. 0.5 mm). Random prostate translations were (1 S.D.) 2.1, 3.2 and 2.2 mm in the lateral (LR), AP and cranial-caudal (CC) directions, respectively, whereas systematic translations were 3.3, 4.8 and 3.5 mm in the LR, AP and CC directions, respectively. Random prostate rotations were (1 S.D.) 3.6, 1.7 and 1.9 degrees around the LR, AP and CC axis, respectively, whereas systematic rotations were 4.7, 2.0 and 2.7 degrees around the LR, AP and CC axis, respectively.
CONCLUSIONS: We found that the fiducial gold seeds are a safe and appropriate device to verify and correct the position of prostate during megavoltage irradiation. The amount of seed migration and prostate deformation is far below our present tumour delineation accuracy.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12865177     DOI: 10.1016/s0167-8140(03)00078-1

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  27 in total

1.  Motion-compensated estimation of delivered dose during external beam radiation therapy: implementation in Philips' Pinnacle(3) treatment planning system.

Authors:  Shyam Bharat; Parag Parikh; Camille Noel; Michael Meltsner; Karl Bzdusek; Michael Kaus
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  The impact of androgen deprivation therapy on setup errors during external beam radiation therapy for prostate cancer.

Authors:  Cem Onal; Yemliha Dolek; Yurday Ozdemir
Journal:  Strahlenther Onkol       Date:  2017-04-13       Impact factor: 3.621

3.  Phantom measurements to quantify the accuracy of a commercially available cone-beam CT gray-value matching algorithm using multiple Fiducials.

Authors:  Frederick Marc Köhler; Judit Boda-Heggemann; Beate Küpper; Dirk Wolff; Hansjörg Wertz; Frank Lohr; Frederik Wenz
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

4.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

Authors:  W Mao; R D Wiersma; L Xing
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

5.  Is it essential to use fiducial markers during cone-beam CT-based radiotherapy for prostate cancer patients?

Authors:  Berna A Yildirim; Cem Onal; Yemliha Dolek
Journal:  Jpn J Radiol       Date:  2016-10-11       Impact factor: 2.374

6.  Real-time adaptive planning method for radiotherapy treatment delivery for prostate cancer patients, based on a library of plans accounting for possible anatomy configuration changes.

Authors:  Maria Antico; Peter Prinsen; Francesco Cellini; Alice Fracassi; Alfonso A Isola; David Cobben; Davide Fontanarosa
Journal:  PLoS One       Date:  2019-02-28       Impact factor: 3.240

7.  Prostate cancer treated with image-guided helical TomoTherapy® and image-guided LINAC-IMRT : Correlation between high-dose bladder volume, margin reduction, and genitourinary toxicity.

Authors:  Sonia Drozdz; Michael Schwedas; Henning Salz; Susan Foller; Thomas G Wendt
Journal:  Strahlenther Onkol       Date:  2016-01-07       Impact factor: 3.621

8.  Postprostatectomy ultrasound-guided transrectal implantation of gold markers for external beam radiotherapy. Technique and complications rate.

Authors:  J F Langenhuijsen; R Donker; G M McColl; L A L M Kiemeney; J A Witjes; E N J T van Lin
Journal:  Strahlenther Onkol       Date:  2013-04-21       Impact factor: 3.621

9.  A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging.

Authors:  Weihua Mao; Nadeem Riaz; Louis Lee; Rodney Wiersma; Lei Xing
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

10.  Clinical commissioning of online seed matching protocol for prostate radiotherapy.

Authors:  A Duffton; S McNee; R Muirhead; A Alhasso
Journal:  Br J Radiol       Date:  2012-12       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.