Literature DB >> 1286420

Clearance of iopamidol, a non-ionic contrast medium, by CAPD in patients with end-stage renal failure.

P K Donnelly1, N Burwell, A McBurney, J W Ward, J Walls, E M Watkin.   

Abstract

In normal healthy subjects radiographic contrast media are cleared by the kidneys with a half-life of approximately 2 h and a total body clearance of 8 l/h. The mechanism of contrast clearance has not been previously investigated in chronic renal failure patients undergoing continuous ambulatory peritoneal dialysis (CAPD). A study was undertaken to investigate the pharmacokinetics of a non-ionic water soluble radiographic contrast medium (iopamidol) in 10 patients stabilized on CAPD. All patients (eight male, two female) aged 22-68 years (median 53 years) had injection of 30 ml of iopamidol 300 via a forearm vein to investigate subclavian vein patency following previous cannulation for haemodialysis. Venous blood samples, CAPD dialysate and urine were collected for seven days post injection. The mean plasma half-life was 37.9 h (SD 10.6) (range 24.1-57.2 h) for the CAPD patients and was greatly prolonged in comparison to healthy subjects. The total body clearance of iopamidol was also greatly reduced (0.377 l/h). CAPD removed an average of 53.6% of the administered dose (range 36.3-80.8%) whilst an average of 26.9% was excreted in the urine (range 1.3-56.3%). The combined renal and dialysate clearance was up to 93% of the administered dose over the period of the study. There is therefore some evidence for a small extra renal clearance of iopamidol in end-stage renal failure patients. This study has shown for the first time that patients with end-stage renal failure undergoing CAPD have significantly delayed elimination of contrast medium. This should be taken into consideration when extensive or prolonged investigations using contrast medium are proposed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1286420     DOI: 10.1259/0007-1285-65-780-1108

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  2 in total

Review 1.  An overview of the clinical pharmacokinetics of x-ray contrast media.

Authors:  M Bourin; P Jolliet; F Ballereau
Journal:  Clin Pharmacokinet       Date:  1997-03       Impact factor: 6.447

2.  Clearance and safety of the radiocontrast medium iopamidol in peritoneal dialysis patients.

Authors:  Shingo Hatakeyama; Akihiko Abe; Takehiro Suzuki; Yasuhiro Hashimoto; Takuya Koie; Tomihisa Funyu; Shigeru Satoh; Tomonori Habuchi; Chikara Ohyama; Shigeki Matsuo
Journal:  Int J Nephrol       Date:  2011-10-19