Temporal artery temperature measurements in healthy infants, children, and adolescents.

Sumita Roy1, Keith Powell, Lowell W Gerson.   

Abstract

A noninvasive temporal artery thermometer that uses arterial heat balance technology has been compared to rectal and ear thermometry and is available in the marketplace. This study was undertaken to establish mean temperatures and temperatures 2 standard deviations above the mean for healthy infants, children, and adolescents. Temperatures were measured in healthy patients 0 to 18 years of age using a noninvasive temporal artery thermometer. Temperatures were measured in 2,346 patients. Mean temperatures and temperatures 2 standard deviations above the mean were: 37.1 degrees C (38.1 degrees C) for 383 infants 0 to 2 months; 36.9 degrees C (37.9 degrees C) for 860 children 3 to 47 months; 36.8 degrees C (37.8 degrees C) for 680 children 4 to 9 years; and 36.7 degrees C (37.8 degrees C) for 423 adolescents 10 to 18 years. There were no significant differences in temperatures in white compared to African-American children, children with or without perspiration on their forehead, or between measurements taken on the left compared to the right side of the forehead. This study provides information about temporal artery temperatures in healthy infants and children that can serve as a basis for interpreting temperature measurements in ill children when the same instrument is used.

Entities:  

Mesh:

Year:  2003        PMID: 12862347     DOI: 10.1177/000992280304200508

Source DB:  PubMed          Journal:  Clin Pediatr (Phila)        ISSN: 0009-9228            Impact factor:   1.168


  5 in total

1.  A comparison of different methods of temperature measurement by mothers and physicians in healthy newborns.

Authors:  Mehmet Yekta Oncel; Kadir Serafettin Tekgunduz; Ramazan Ozdemir; Erhan Calisici; Sevilay Karahan; Omer Erdeve; Serife Suna Oguz; Ugur Dilmen
Journal:  Indian J Pediatr       Date:  2012-06-02       Impact factor: 1.967

2.  Noninvasive temporal artery thermometry as an alternative to rectal thermometry in research macaques ( Macaca spp.).

Authors:  Stephanie E Woods; Robert P Marini; Mary M Patterson
Journal:  J Am Assoc Lab Anim Sci       Date:  2013       Impact factor: 1.232

3.  Evaluation of the Cadi ThermoSENSOR wireless skin-contact thermometer against ear and axillary temperatures in children.

Authors:  Kim-Gau Ng; Sook-Thow Wong; Soh-Min Lim; Zenton Goh
Journal:  J Pediatr Nurs       Date:  2009-04-18       Impact factor: 2.145

4.  Thermometry in children.

Authors:  Prerna Batra; Abhijeet Saha; Moonis Mohammed Akbar Faridi
Journal:  J Emerg Trauma Shock       Date:  2012-07

5.  A comparison of temporal artery thermometers with internal blood monitors to measure body temperature during hemodialysis.

Authors:  Meaghan Lunney; Bronwyn Tonelli; Rachel Lewis; Natasha Wiebe; Chandra Thomas; Jennifer MacRae; Marcello Tonelli
Journal:  BMC Nephrol       Date:  2018-06-14       Impact factor: 2.388

  5 in total