Literature DB >> 12862243

A survey of 14 computed tomography scanners in Greece and 32 scanners in Italy. Examination frequencies, dose reference values, effective doses and doses to organs.

D Papadimitriou1, A Perris, A Manetou, M Molfetas, N Panagiotakis, M Lyra-Georgosopoulou, K Hourdakis, S Kottou, G Tosi, D Origgi, S Vigorito.   

Abstract

A survey of examination frequencies, dose reference values, effective doses and doses to organs involving 14 scanners from Greece and 32 scanners from Italy was carried out for the years 1999 and 2000. Examination frequencies per scanner and per year were found to be 3590 for Greece and 4520 for Italy. For the types of examinations considered, CDTI(W) and DLP measurements were taken. Also scan lengths used for the same types of examinations were monitored. For the same types of examinations effective doses were calculated by two methods, and it was found that their mean values ranged from 13.1 mSv for thoracic spine to 1.6 mSv for the brain examinations. From the data of the 14 Greek laboratories, doses to organs were calculated and it was found that the thyroid receives 50.2 +/- 19.8 mGy during a cervical spine examination while the gonads receive 17.8 +/- 6.9 mGy during a routine pelvis examination.

Mesh:

Year:  2003        PMID: 12862243     DOI: 10.1093/oxfordjournals.rpd.a006162

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose-length product and the effective dose and to verify fulfilment of the diagnostic reference levels.

Authors:  Daniela Origgi; Sabrina Vigorito; Gaetano Villa; Massimo Bellomi; Giampiero Tosi
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

2.  Patient doses from CT examinations in Turkey.

Authors:  Gökçe Kaan Ataç; Aydın Parmaksız; Tolga İnal; Emine Bulur; Figen Bulgurlu; Tolga Öncü; Sadi Gündoğdu
Journal:  Diagn Interv Radiol       Date:  2015 Sep-Oct       Impact factor: 2.630

3.  Dose management in CT facility.

Authors:  V Tsapaki; M Rehani
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

4.  Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination.

Authors:  Hung-Chih Lin; Te-Jen Lai; Hsien-Chun Tseng; Ching-Hsiang Wang; Yen-Ling Tseng; Chien-Yi Chen
Journal:  J Radiat Res       Date:  2019-07-01       Impact factor: 2.724

  4 in total