Literature DB >> 12858882

Indoor air quality in the university libraries of Modena (Italy).

G Fantuzzi1, G Aggazzotti, E Righi, L Cavazzuti, G Predieri, A Franceschelli.   

Abstract

We carried out a survey in 16 libraries of the University of Modena, Northern Italy, to assess the indoor exposure to volatile organic compounds (VOCs), including formaldehyde, and total dusts. Data were collected on the main structural characteristics of the buildings; indoor microclimate parameters, such as temperature, relative humidity and ventilation rate were measured and air samples taken inside and outside the libraries. The mean value of total dusts was 190 +/- 130 microg/m3 with a wide range of values. Formaldehyde was found in only ten out of 16 libraries and the indoor concentrations ranged from 1.70 to 67.8 microg/m3 with an average value of 32.7 +/- 23.9 microg/m3. On the whole, VOCs were present in all the libraries investigated with an average value was 433 +/- 267 microg/m3 (range 102-936 microg/m3). No correlation was found among VOCs, formaldehyde and total dusts nor was a significant association observed with microclimatic parameters or the structural characteristics of the buildings. The general situation found in this study suggests no major problems related to indoor pollution. However, some of the pollutants investigated such as total dust and total VOCs deserve further investigation. It is important to identify the possible sources of contaminants and to define the relationship between indoor and outdoor levels of pollutants more accurately, taking into account the effects of air recycling due to natural ventilation systems.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 12858882     DOI: 10.1016/s0048-9697(96)05335-1

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  5 in total

1.  Distribution of polycyclic aromatic hydrocarbons in aerosols and dustfall in Macao.

Authors:  Q Shihua; Y Jun; Z Gan; F Jiamo; S Guoying; W Zhishi; S M Tong; U W Tang; M Yunshun
Journal:  Environ Monit Assess       Date:  2001-11       Impact factor: 2.513

2.  Assessment of indoor air concentrations of VOCs and their associated health risks in the library of Jawaharlal Nehru University, New Delhi.

Authors:  Amit Kumar; Bhupendra Pratap Singh; Monika Punia; Deepak Singh; Krishan Kumar; V K Jain
Journal:  Environ Sci Pollut Res Int       Date:  2013-09-18       Impact factor: 4.223

3.  Levels, sources, and health risks of carbonyls in residential indoor air in Hangzhou, China.

Authors:  Mili Weng; Lizhong Zhu; Kun Yang; Shuguang Chen
Journal:  Environ Monit Assess       Date:  2009-04-08       Impact factor: 2.513

Review 4.  Monitoring biodiversity in libraries: a pilot study and perspectives for indoor air quality.

Authors:  F Valeriani; C Cianfanelli; G Gianfranceschi; S Santucci; V Romano Spica; N Mucci
Journal:  J Prev Med Hyg       Date:  2017-09

5.  Investigation of indoor air quality in university libraries in terms of gaseous and particulate pollutants in Bartin, Turkey.

Authors:  Gülten Güneş; Nesibe Yalçin; Huriye Çolaklar
Journal:  Environ Monit Assess       Date:  2022-02-19       Impact factor: 3.307

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.