Eccentric correction for off-axis vision in central visual field loss.

Jörgen Gustafsson1, Peter Unsbo.   

Abstract

BACKGROUND: Subjects with absolute central visual field loss use eccentric fixation and magnifying devices to utilize their residual vision. This preliminary study investigated the importance of an accurate eccentric correction of off-axis refractive errors to optimize the residual visual function for these subjects.
METHODS: Photorefraction using the PowerRefractor instrument was used to evaluate the ametropia in eccentric fixation angles. Methods were adapted for measuring visual acuity outside the macula using filtered optotypes from high-pass resolution perimetry. Optical corrections were implemented, and the visual function of subjects with central visual field loss was measured with and without eccentric correction.
RESULTS: Of the seven cases reported, five experienced an improvement in visual function in their preferred retinal locus with eccentric refraction.
CONCLUSIONS: The main result was that optical correction for better image quality on the peripheral retina is important for the vision of subjects with central visual field loss, objectively as well as subjectively.

Entities:  

Mesh:

Year:  2003        PMID: 12858089     DOI: 10.1097/00006324-200307000-00015

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  6 in total

1.  Peripheral vision and hazard detection with average phakic and pseudophakic optical errors.

Authors:  Abinaya Priya Venkataraman; Robert Rosén; Aixa Alarcon Heredia; Patricia Piers; Carmen Canovas Vidal; Linda Lundström
Journal:  Biomed Opt Express       Date:  2021-05-03       Impact factor: 3.732

2.  Compensation of corneal oblique astigmatism by internal optics: a theoretical analysis.

Authors:  Tao Liu; Larry N Thibos
Journal:  Ophthalmic Physiol Opt       Date:  2017-03-09       Impact factor: 3.117

3.  Instrument for fast whole-field peripheral refraction in the human eye.

Authors:  Enrique J Fernandez; Santiago Sager; Zhenghua Lin; Jiangdong Hao; Javier Roca; Pedro M Prieto; Zhikuang Yang; Weizhong Lan; Pablo Artal
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

4.  Influence of uncorrected ametropia on computer-based perimetry in patients with visual field defects and normal subjects.

Authors:  Sandra Jobke; Erich Kasten; Bernhard A Sabel
Journal:  Clin Ophthalmol       Date:  2007-06

5.  Transverse chromatic aberration across the visual field of the human eye.

Authors:  Simon Winter; Ramkumar Sabesan; Pavan Tiruveedhula; Claudio Privitera; Peter Unsbo; Linda Lundström; Austin Roorda
Journal:  J Vis       Date:  2016-11-01       Impact factor: 2.240

6.  Choice of Grating Orientation for Evaluation of Peripheral Vision.

Authors:  Abinaya Priya Venkataraman; Simon Winter; Robert Rosén; Linda Lundström
Journal:  Optom Vis Sci       Date:  2016-06       Impact factor: 1.973

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.